OPERATING
INSTRUCTIONS
SZ-7510-P-DI
www.subzero.co
1
4
GENERAL DESCRIPTION
The Sub-Zero Series SZ-7510-P-DI are aesthetically superior
versions of their predecessors. The SZ-7510-P-DI is a single
set point controller. with digital input. They are specifically
designed for refrigeration applications wherein the
compressor cuts off at set point and is restarted at a
temperature of set point plus differential.
Additionally these controllers offer several protection features
that are easily understood by the examples in the instructions
below. The controller can be used for heating applications,
when the P1 parameter is set to “1” .
A number of parameters are displayed alphanumerically to set
up the instrument for each specific application.
The SZ-7510-P-DI controller can be used for several
O
O
applications with a measuring range from -50 C to 99 C.
Instructions
:
Function: To set the cut out
point of the controller.
Display will change to set range.
The set point range can now be
changed by using the UP/DOWN
key. After setting the desired
range, press the set key and you
will see “- - -” which confirms that
the set point has been stored in
memory.
Set point
Press and hold
the SET
key for
2 Seconds.
O
-50 C
O
99 C
O
10 C
Min
Max
Fac.
3
INDEX
Para.
Page
Description
P1
P2
P3
P4
P5
P6
d0
d1
d2
d3
LP
E1
FS
EP
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
2
INDIA
To set other
Parameters.
Display will show P1 & flash.
To go to other parameters,
use UP/DOWN keys.
Press & hold
the DOWN(prg)
key for
2 seconds.
prg
SET
To set the SET Point of the controller.
How to set other parameters.
To set Heating or Cooling function.
Max High Temp limit & alarm.
Min Low Temp limit & alarm.
To set Differential (Hysterisis).
Probe calibration.
Time Delay (relay restart after cutoff)
Keypad lock.
Relay status on probe failure.
Restore factory defaults.
End Programming.
Operating messages.
Technical Data.
Wiring diagram.
Panel cutout & dimensions.
Activate or deactive digital input function.
Set reset mode for digital input
Set the count mode for CCF
Set the number of count for CCF