 WARNING

: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED

EXACTLY, A FIRE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL

INJURY, OR LOSS OF LIFE.

– Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any 

other appliance.

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do not use any phone in your building.

•  Immediately call your gas supplier from a neighbor’s phone. Follow the gas

 

supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire department.

– Installation and service must be performed by a qualified installer, service agency

  or the gas supplier.

This appliance may be installed in an aftermarket, permanently located manufactured 

(mobile) home, where not prohibited by local codes. This appliance is for use with the 

type of gas indicated on the rating plate only. This appliance is not convertible for use 

with other gases.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is 

installed. Provisions for adequate combustion and ventilation air must be provided. 

Refer to 

Air For Combustion and Ventilation 

section on page 8 of this manual.

INSTALLER : DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER'S 

FUTURE REFERENCE.

LS-SSFBD32RT-1002

Questions, problems, missing parts?

 Before returning to your retailer, contact 

our customer service department at 1-866-573-0674, 8:00 a.m - 4:30 p.m., 

EST, Monday - Friday or e-mail [email protected].

 WARNING

: This appliance 

is equipped for (Natural and 

Propane) gas. Field conversion is 

not permitted other than between 

natural or propane gases.

 

 

 ITEM #0293807

VENT-FREE GAS FIREPLACE INSERT 

 

MODEL #SSFBD32RT

 CAUTION - FOR YOUR SAFETY

Español p. 37

Содержание SSFBD32RT

Страница 1: ...not prohibited by local codes This appliance is for use with the type of gas indicated on the rating plate only This appliance is not convertible for use with other gases This is an unvented gas fire...

Страница 2: ...85 in x 40 19 in x 20 49 in Weight lbs Stove 88 2 Shipping 105 4 Safety Information 3 Product Features 6 Air For Combustion and Ventilation 8 Installation 11 Installing Logs 20 Operation 22 Care and...

Страница 3: ...pane LP gases are odorless An odor making agent is added to the gas The odor helps you detect a gas leak However the odor added to the gas can fade Gas may be present even though no odor exists Make c...

Страница 4: ...ff If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture 7 Always run heater with control knob at PILOT or ON locked positions...

Страница 5: ...ng and the heater burning manufacturing residues QUALIFIED INSTALLING AGENCY Only a qualified agency should perform installation and replacement of gas piping gas utilization equipment or accessories...

Страница 6: ...ers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented propane or natu...

Страница 7: ...om heater produces approximately one 1 ounce 30 mL of water for every 1 000 BTUs 3 kw of gas input per hour An unvented room heater is recommended as a supplemental heater a room rather than a primary...

Страница 8: ...gate input rating of all appliances installed in that space Rooms connecting directly with the space in which the appliances are installed through openings not furnished with doors are considered a pa...

Страница 9: ...er logs ________ BTU hr Gas water heater 30 000 BTU hr Other gas appliances ___BTU hr Vent free heater 26 000 BTU hr Total ________________ BTU hr Total 56 000 BTU hr Do not include direct vent gas ap...

Страница 10: ...a thermostat controlled power vent Heated air entering the attic will activate the power vent Rework worksheet adding the space of the adjoining unconfined space The combined spaces must have enough f...

Страница 11: ...lamps etc in the air exist may cause walls to discolor WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent...

Страница 12: ...h opening The height is 28 11 in which is the same as the wall opening above 2 Carefully set fireplace in front of rough opening with back of fireplace inside wall opening 3 Attach gas line to firepla...

Страница 13: ...not allow any combustible materials to overlap the firebox front WARNING Do not allow combustible or noncombustible materials to cover any necessary openings like louvered slots WARNING Never modify o...

Страница 14: ...ible gas hose check local code A CSA design certified equipment shutoff valve with 1 8 in NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA design certified equip...

Страница 15: ...e recommend that you install a sediment trap in a supply line as shown in Fig 12 Locate sediment trap where it is within reach for cleaning and not likely to freeze Install in the piping system betwee...

Страница 16: ...of a quarter and turn knob clockwise until the knob locks into the NG position see Fig 14 3 Rotate and close cover over gas selection valve and reinstall screw 4 Remove steel or metal hex plug with wr...

Страница 17: ...17 Fig 15 Fig 14 Fig 13 NATURAL GAS PROPANE GAS PLUG PLUG PROPANE GAS NATURAL GAS NATURAL GAS PROPANE GAS...

Страница 18: ...may be a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1...

Страница 19: ...r consumption is higher than standard remote control systems 1 Take Control Box out from Control Panel See Fig 20 2 Remove battery cover along the direction showed on the battery box and install four...

Страница 20: ...the log 4 on the right front angle STEP 5 Install the log 5 on the left front angle WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically a...

Страница 21: ...P 7 Insert the pinhole on the upper part of log 7 in the pin on log 1 log 3 and log 5 STEP 8 Insert the pinhole on the upper part of log 8 in the pin on the log 4 and log 2 STEP 9 Insert the pinhole o...

Страница 22: ...s heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call...

Страница 23: ...step 8 Push the control knob in slightly and turn counterclockwise to PILOT position and depress for five 5 seconds Note The first time the heater is operated after connecting the gas supply the contr...

Страница 24: ...2 F or C Indicates degrees Fahrenheit or Celsius 3 FLAME Indicates burner valve in operation 4 ROOM Indicates remote is in THERMO operation 5 TEMP Appears during manual operation 6 SET Appears during...

Страница 25: ...reached By pressing and holding the set key the LCD screen set numbers will increase from 45 to 99 and then restart over at 45 Next release the SET key The LCD screen will display the set temperature...

Страница 26: ...to the transmitter This is part of the system s design MATCHING SECURITY CODES Program the remote receiver to LEARN a new security code by pushing in the LEARN button the top of the remote receiver a...

Страница 27: ...ame Pattern with Control Knob Set to High Flame 5 Fig 37 Incorrect Pilot Flame Pattern with Control Knob Set to High Flame 5 BURNER FLAME PATTERN Fig 36 shows a correct burner flame pattern Fig 37 sho...

Страница 28: ...er Repeat steps 3 and 4 Clean the pilot assembly also WARNING Failure to keep primary air openings of burners clean may result in sooting and property damage CAUTION You must keep control areas burner...

Страница 29: ...ole You may blow through a drinking straw if compressed air is not available CABINET Air Passageways Use a vacuum cleaner or pressurized air and a small soft bristled brush to clean Exterior Use a sof...

Страница 30: ...wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace electro...

Страница 31: ...orifice 3 Contact your gas supplier Delayed ignition of burner s 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Contact your gas supplier 2 Clean burner see Care and Maintenance page 28...

Страница 32: ...r furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products H...

Страница 33: ...Customer Service have ready Your name Your address Model and serial number of your heater How heater was malfunctioning Type of gas used Propane LP or Natural gas NG Purchase date Usually we will ask...

Страница 34: ...7 FB32D507 1 12 Log 8 FB32D508 1 13 Log 9 FB32D509 1 14 Screen FB32D100 1 15 Remote Control CON 1001TH 1 16 Lower Front Access Door FB32D110 1 17 Upper Decorative Trim FB32D104 1 18 Left Right Decorat...

Страница 35: ...35 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 18 22 19 20 21...

Страница 36: ...ccident misuse improper installation or by affixing accessories not produced by the manufacturer are the purchaser s responsibility The manufacturer assumes no responsibility whatsoever for installati...