background image

Sturtevant Richmont 

3203 N. Wolf Road 

Franklin Park, IL   60131 

Phones:  847/455-8677   800/877-1347  Fax:  847/455-0347 

[email protected]

   

www.srtorque.com

 

 

Operating Instructions 

Micrometer Adjustable Torque Wrench Series  (SDR, SD, & CCM Models)

 

 

Sturtevant Richmont 

micrometer adjustable torque wrenches are designed & manufactured to provide consistent and 

rapid user-selectable torque in a variety of manufacturing and maintenance operations.  They meet or exceed ASME 
B107.14M and ISO 6789.  These wrenches are accurate to +/- 4% of indicated value from 20% to 100% of capacity. 
 

The Ratchet and Square Drive tools operate & deliver torque in one direction only, as indicated by the arrow on 

the case (Figure 1). The wrench will not indicate torque but can be used in the reverse direction, provided you do not 
exceed the rated capacity of the wrench.  The Dovetail series can be used in either direction with the same accuracy by 
removing the head and turning the wrench 180 degrees. 

 

 

 

 

 

 

 
To set the desired torque: 

The case (Figures 1 & 2) is engraved with graduations (major scale) and the aluminum grip with increments 

(minor scale).  The torque setting is the sum of the largest graduation below the end of the aluminum grip plus the 
increment aligned with the centerline of the graduations.  One complete revolution of the grip is equal to one graduation 
on the major scale. 
 

To set the desired torque, rotate the grip lock (Figure 3) in the unlock direction until the grip can be readily rotated. 

Next, grasp the case firmly with one hand and rotate the rubber grip clockwise (CW) to increase torque or counter-
clockwise (CCW) to decrease torque.  Once the desired torque has been set, lock the grip lock by rotating it in the lock 
direction until it stops.  Recheck torque to confirm proper setting. 
 

To use the torque wrench: 

1)  Attach appropriate fastener engagement device (socket, S/R interchangeable head, etc.) to the wrench.  

Note

: It is 

imperative the fastener engagement device maintain the same lever length as was used during calibration.  Failure to 
maintain lever length will cause applied torque to differ from set torque. 

2)  Engage the fastener while holding the wrench perpendicular to the axis of the fastener. 
3)  Grip the center of the vinyl grip and with a steady force pull in the direction of the arrow on the case. 
4)  Continue to pull the wrench until an audible/tactile impulse (the “click”) is experienced. 
5)  Stop pulling immediately to prevent over torquing.  
 
 

CARE & CLEANING 

 

Always store wrench in a clean dry environment. 

Do Not

 immerse wrench in cleaning fluids. It is further suggested that if 

the wrench is to sit idle for very long periods of time it should be set

 

to its lowest setting. 

 

Calibration Instructions 

Required Equipment:

  Torque analyzer or tester accurate  to 1% of indicated value or better, four (4) hex keys (5/64”, 

3/32”, 5/32”, & 5/16”), and a torch*.  *Required only if solder used on grip lock or access screw. 
 

Figure 1 

Figure 3

Figure 2