1 General
Information
1.1 Operating
instructions
This manual is a part of the delivery package of every XP-COMPACT inverter-charger. It serves as
guidelines for safe and efficient operation of XP-COMPACT. The instructions are only valid for use
with the following appliances and options:
-
XP-COMPACT XPC 1400-12
-
XP-COMPACT XPC 2200-24
-
XP-COMPACT XPC 2200-48
-
Temperature sensor CT-35
- Remote control RCC-01
-
Solar charge controller XPCxxxx-S
-
AC cable cover CFC-01
-
IP-23 top cover C-IP23
Every person who installs a XP-COMPACT and/or works with it must be fully familiar with the con-
tents of this manual and must follow exactly all the warnings and safety instructions. Installation of
or any work on the XP-COMPACT must be carried out by a qualified and trained staff. Installation
and application must comply with the respective local installations codes and safety regulations.
1.2 Quality
and
Warranty
During production and assembling, all XP-COMPACT appliances go through many controls and
tests. Production, controls and tests are carried out in accordance with firm and established pro-
cedures. Every XP-COMPACT has its own serial number, which helps to refer back to its original
data in the event of controls or repairs. That is why you should never remove the identification
plate showing the serial number. The production assembly and tests on all XP-COMPACT appli-
ances are totally carried out in our company in Sion, Switzerland. The warranty for these appli-
ances is valid for uses and operating possibilities mentioned in this manual.
The warranty period for the XP-COMPACT is 2 years.
1.3 Warranty
Disclaimer
We do not accept any responsibility for any damages occurring through use, manipulation, working
situation and handling, which are not explicitly mentioned in these operating instructions.
Following cases are not covered by the warranty:
•
High voltage at INPUT (i.e. 48V at the Battery INPUT of XP-COMPACT 1400-12)
•
Reverse polarity on Battery connections (+/- reversed)
•
Running liquid or oxidation through condensation in the appliance
•
Defects caused by force, physical or mechanical means
•
Changes not explicitly authorized by STUDER INNOTEC
•
Not or only partly tightened screws and nuts after change of fuses or connecting cables
•
Connecting other sources of energy such as PV-Modules on the INPUT „SOLAR +/-„
•
Transport damage, i.e. through bad handling and /or packing
•
Damage from atmospheric over voltage
1.4 Liability
Disclaimer
Respecting this manual, servicing and method of installation, functioning, application and mainte-
nance of the appliance can not be controlled or supervised by STUDER INNOTEC. Hence we do
not accept any liability and responsibility for damages, loses and costs which result through the
use of this appliance or which result through incorrect installation, incorrect operation or wrong
application and maintenance or which by some other means maybe connected together to these.
Similarly, we do not accept any responsibility for any violation of the patents rights or violation of
any third party’s rights resulting from the use of this appliance
STUDER INNOTEC reserves the right to modify the technical data or these operating instructions