Studer Innotec SA
VarioString
22
User manual
5
POWER-UP OF THE EQUIPMENT
The connection of the VarioString must be carried out in the following order. Any disassembly shall
be carried out in the reverse order. Before closing the protections and energizing the equipment,
check the polarity.
A.
Connecting the battery: on the BAT+ and BAT- terminals
Check that the VarioString switches on (green LED “NIGHT” lights up on the control panel)
B.
Connecting the photovoltaic panels: on the PV+ and PV- terminals
Check the PV voltage seen on the RCC. (if present)
Check the operation of the charger and the effective charging of the batteries when it is
sunny.
Your installation is now in operation. If the system requires specific configurations or settings, carry
them out immediately. Settings must be programmed by means of the remote control RCC-02/03 as
per chap. 9.2 or by means of the internal DIP switches as per chap. 9.1.
Saving of data in the datalog is activated only after the VarioString has completed the automatic
detection of the cabling type of the PV generators. In the case that the cabling configuration is
entered manually, the datalog is activated immediately.
It is imperative that the closing cover for the connection compartment is installed and
screwed tight before energizing the installation. There are dangerous voltages inside the
cable compartment.
If special configurations or settings are required for the system and they are set via internal
buttons or switches (DIP switch, see chap. 9.1), they should be set before connecting the
PV modules.
When connecting the cable to the second battery pole there will be a spark. This is normal.
If the VarioString has been accidentally connected in reverse (battery reverse polarity on
the panel input), it is likely that the protection device on the battery cables is open. In that
case, carefully check the battery polarity, the wiring and the VarioString's internal fuse (VS-
70 : 80V, 100A) (VS-120 : CF8, 58V, 150A) that protects against this situation. If the VarioString
still does not work, after having closed or replaced the protection device (f) (chap. 12.1),
despite having a correct polarity and voltage of the battery, it must be brought back to
your reseller for repair.
Содержание VarioString VS-120
Страница 2: ...Studer Innotec SA VarioString 2 V 2 3 User manual ...
Страница 13: ...Studer Innotec SA VarioString User manual V 2 3 13 4 1 2 VarioString VS 120 ...
Страница 61: ...Studer Innotec SA VarioString User manual V 2 3 61 ...
Страница 62: ...Studer Innotec SA VarioString 62 V 2 3 User manual ...
Страница 63: ...Studer Innotec SA VarioString User manual V 2 3 63 ...