![STUCCHI MULTISYSTEM Series Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/stucchi/multisystem-series/multisystem-series_instructions-manual_1386414003.webp)
The track bars with 1-2-3 m length are supplied with the copper conductors already recessed at
each finished edge, to prevent them coming from into contact with one another in case of dual
power supply or, if end caps are used, to prevent the copper conductors from coming into contact
with them. If the track must be shortened during installation, after cutting it use the special pliers (S-
9000/T) to cut back the 4 copper conductors of the track (Fig.4.). Make sure to remove the 4 pieces
of copper conductor cut (Fig.5.). Proceed with the installation of another track or apply the end
caps as explained in the instruction sheet.
Recessing
track
conductors
Recessing track conductors
End Caps
3
11/7/2019
Содержание MULTISYSTEM Series
Страница 10: ...10 11 7 2019...