Maintenance
7.5
Installing
Install components concentrically and without tilting in
accordance with the markings applied.
Apply graphite paste to metallic connections prior to
assembly.
WARNING
Risk of injury due to heavy components!
Pay attention to the component weight. Lift and transport
heavy components using suitable lifting gear.
Set down components safely and secure them against
overturning or rolling away.
WARNING
Risk of injury during assembly!
Install spring-loaded components carefully (e.g. mechan-
ical seal, tensioned bearing, valves etc.), as components
can be ejected by the spring tension.
Observe the manufacturer's speci
fi
cations (e.g. for the
motor, coupling, mechanical seal, blocking pressure sys-
tem, cardan shaft, drives, belt drive etc.).
NOTE
Material damage due to incorrect dismounting/installation
of the pump.
Only specialist mechanics should complete dismounting/
installation work.
NOTE
Material damage due to unsuitable components!
Always replace lost or damaged screws with screws of the
same strength where required (
of casing screws, Page 34).
Only replace seals with seals of the same material.
NOTE
Material damage, fragile components
Mount ceramic parts of the plain bearing with care, do not
hit or knock.
1. When installing please observe:
–
Replace worn parts with genuine spare parts.
–
Replace seals, inserting them in such a way that they
are unable to rotate.
–
Do not apply synthetic or mineral oil, grease or cleaning
agents to elastomer components.
–
Use only silicon-based oils and greases.
–
Observe the prescribed tightening torques:(
ightening torques of casing screws, Page 34).
–
Shaft protection sleeve without locking pin
2. Installing the pump:
–
in reverse order to the dismounting
Removing:
(
7.3.3 Dismantling SHB 32–125 to 100–200,
7.6 Aligning pump and motor shaft, SHB 15–80 to
7.7 Aligning pump and motor shaft, SHB 32-125 to
–
→
sectional drawing
3. Install the pump in the system.
300 486