Stübbe SHM 20-15 Скачать руководство пользователя страница 17

Installation and connection

5.4

Connecting the pipes

NOTE

Material damage due to excessive forces and torques on
the pump.

Ensure pipe connection without stress.

5.4.1

Keeping the piping clean

NOTE

Material damage due to impurities in the pump!

Make sure no impurities can enter the pump.

1. Clean all piping parts and fittings prior to assembly.
2. Flush all pipes carefully with neutral medium.
3. Ensure no flange seals protrude inwards.
4. Remove any blind flanges, plugs, protective foils and/or

protective paint from the flanges.

5.4.2

Installing suction pipe

1. Remove the transport and sealing covers from the pump.
2. Fit suction pipe stress-free and sealed.

(

9.2.3 Flange

tightening torques, Page 32).

3. Ensure no seals protrude inwards.
4. For the suction process: Install foot valve in the suction

pipe in order to prevent the pump and suction pipe from
dry running when pump is not running.

5.4.3

Installing the pressure pipe

1. Remove the transport and sealing covers from the pump.
2. Fit

the

pressure

line

stress-free

and

sealed

(

9.2.3 Flange tightening torques, Page 32).

3. Ensure no seals protrude inwards.

5.4.4

Inspection for stress-free pipe connections

Piping installed and cooled down

1. Disconnect the pipe connecting flanges from the pump.
2. Check whether the pipes can be moved freely in all direc-

tions within the expected range of expansion:

Nominal width < 150 mm: by hand

Nominal width > 150 mm: with a small lever

3. Make sure the flange surfaces are parallel.
4. Reconnect the pipe connecting flanges to the pump.
5. If present, check support foot for stress.

5.5

Electrical connection

DANGER

Risk of electrocution!

All electrical work must be carried out only by qualified elec-
tricians.
Before all work on the electrical system, disconnect the
motor from the mains and secure against being switched
back on again.

5.5.1

Connecting the motor

Follow the instructions of the motor manufacturer.

1. Connect the motor according to the connection diagram.
2. Make sure no danger arises due to electric power.
3. Install an EMERGENCY STOP switch.

5.5.2

Check direction of rotation

Only possible when starting up

(

6.2 Commissioning,

Page 18).

5.6

Performing the hydrostatic test

Only necessary if the entire system needs to be tested
under pressure.

NOTE

Material damage due to bursting of pump casing.

Testing pressure must not exceed the permissible pump
pressure (

documents for the particular order).

Make sure the testing pressure does not exceed the per-
missible pump pressure.

If necessary, do not perform pressure test on the pump.

300 092

BA-2018.08.21 EN

SHM

17

Содержание SHM 20-15

Страница 1: ...ion BA 2018 08 21 EN Print No 300 092 TR MA DE Rev004 ST BBE GmbH Co KG Hollwieser Stra e 5 32602 Vlotho Germany Phone 49 0 5733 799 0 Fax 49 0 5733 799 5000 E mail contact stuebbe com Internet www st...

Страница 2: ...s 17 5 4 1 Keeping the piping clean 17 5 4 2 Installing suction pipe 17 5 4 3 Installing the pressure pipe 17 5 4 4 Inspection for stress free pipe connections 17 5 5 Electrical connection 17 5 5 1 Co...

Страница 3: ...3 Measures to be taken if the pump is shut down 19 Tab 4 Measures depending on the behavior of the pumped liquid 19 Tab 5 Fault number assignment 26 Tab 6 Troubleshooting list 28 Tab 7 Designation of...

Страница 4: ...ollow this manual and the other applicable documents especially all safety instructions and warnings 1 2 Other applicable documents Document purpose Where found ATEX additional manual 300 365 Addition...

Страница 5: ...azardous situation Minor injury Potentially hazardous situation Material damage Safety warning sign Take note of all information highlighted by the safety warning sign and follow the instructions to a...

Страница 6: ...flow and speed data sheet The power consumption of the pump increases as the spe cific gravity of the pumped fluid increases Adhere to the permissible specific gravity in order to eliminate the pos si...

Страница 7: ...cold and moving parts pump safety guarding provided by the customer For pumps without capability to run dry Dry run pro tection For potential electrostatic charging provide suitable grounding Warranty...

Страница 8: ...itional manual Additional instructions for use in explosive atmospheres www stuebbe com pdf_manuals 300365 pdf 2 3 3 Magnetic field The magnetic field of the magnetic coupling can destroy prod ucts th...

Страница 9: ...7 Fig 1 Name plate example 1 Pump type 2 Serial number 3 Ident number 4 Housing sealing material 5 Shaft seal information 6 Impeller diameter mm 7 Differential head 8 Flow 3 1 2 ATEX type plate Typ Se...

Страница 10: ...Layout and Function 3 2 Description Non self priming horizontal centrifugal pump Magnetically coupled and hermetically sealed 10 SHM BA 2018 08 21 EN 300 092...

Страница 11: ...n flange 2 Pressure flange 3 Magnetic coupling 4 Terminal box 5 Motor 6 Base frame 7 Volute casing 3 4 Shaft seals Only one of the following shaft seals is used 3 4 1 Magnetic coupling Magnetic coupli...

Страница 12: ...cking and inspection on delivery 1 Unpack the pump pump assembly upon delivery and inspect it for transport damage 2 Check completeness and accuracy of delivery 3 Ensure that the information on the na...

Страница 13: ...pump properly 1 Seal all openings with blind flanges blind plugs or plastic covers 2 Make sure the storage room meets the following condi tions Dry Frost free Vibration free UV protected 3 Rotate the...

Страница 14: ...ns 9 2 1 Ambient conditions Page 32 5 1 2 Preparing the installation site Ensure the installation site meets the following conditions Pump is freely accessible from all sides Sufficient space for the...

Страница 15: ...1 Fill the anchoring holes with mortar casting compound 2 When the mortar casting compound has set bolt the base plate at three points to the specified tightening torque 3 Before tightening the remai...

Страница 16: ...y and control devices recommended Avoid contamination 1 Install filters in the suction pipe 2 Install a differential pressure gauge with contact manome ter to monitor contamination Avoid reverse runni...

Страница 17: ...cooled down 1 Disconnect the pipe connecting flanges from the pump 2 Check whether the pipes can be moved freely in all direc tions within the expected range of expansion Nominal width 150 mm by hand...

Страница 18: ...on Page 17 6 2 Commissioning 6 2 1 Switching on Pump set up and connected properly Motor set up and connected properly Align motor precisely to the pump All connections stress free and sealed All safe...

Страница 19: ...back on again WARNING Risk of injury and poisoning due to hazardous pumped liquids Use protective equipment for any work on the pump Collect leaking liquid safely and damage fitting in accor dance wi...

Страница 20: ...stomer seals O rings shaft sealing rings 6 5 Operating the stand by pump Stand by pump filled and bled Operate the stand by pump at least once a week 1 Fully open the suction side fitting 2 Open press...

Страница 21: ...itions reduce the service life of antifriction bearings Plain bearings are subject to natural wear and tear which is heavily dependent on the respective operating condi tions It is therefore not possi...

Страница 22: ...keep a safe distance of 1 m Make sure that no magnetizable metal parts can be attracted by the pump s magnetic coupling Make sure that parts of the magnetic coupling cannot be attracted by the magneti...

Страница 23: ...ce Pressure gauge lines pressure gauge and fixtures dis mounted WARNING Risk of injury during disassembly work on the magnetic coupling Use jacking screws to disassemble the bearing bracket in order t...

Страница 24: ...e casing 102 1 11 Remove the impeller 230 1 from the shaft 210 1 12 Remove thrust bearing 314 3 from the volute casing 13 Remove thrust bearing 314 4 from the impeller 14 Remove thrust bearing 314 5 f...

Страница 25: ...motor coupling mechanical seal blocking pressure sys tem cardan shaft drives belt drive etc WARNING Risk of injury during assembly work on the magnetic cou pling Use jacking screws to assemble the be...

Страница 26: ...ossible faults are identified by a fault number in the table below This number identifies the respective cause and rem edy in the troubleshooting list Fault Number Pump not pumping 1 Pumping rate insu...

Страница 27: ...e pipe Install a larger impeller and consult the manufacturer X X X Pressure side fitting not opened wide enough Open the pressure side fitting X X X Magnetic coupling has parted Switch off pump and s...

Страница 28: ...impeller X X X Hydraulic parts of the pump dirty clotted or encrusted Dismount the pump Clean the parts X X Plain bearing faulty Replace plain bearing X Defective antifriction bearing in motor Replac...

Страница 29: ...ring 412 5 Sealing ring 505 1 Reinforcement ring 545 1 Bearing bush 554 1 Washer 554 2 Washer 554 3 Washer 580 1 Protection cap 580 2 Protection cap 580 3 Protection cap 801 1 Motor 817 1 Rear cover 8...

Страница 30: ...ix 9 1 2 Drawing SHM 20 15 855 1 904 1 314 5 545 1 412 5 210 1 545 1 230 1 314 3 102 1 817 1 554 2 901 2 934 1 554 1 901 1 580 1 801 1 341 1 Fig 7 Replacement parts SHM 20 15 30 SHM BA 2018 08 21 EN 3...

Страница 31: ...314 5 412 5 210 1 545 1 230 1 314 3 102 1 901 1 554 1 934 1 723 4 314 4 505 1 891 1 801 1 904 1 412 2 723 3 723 1 412 1 341 1 901 3 934 3 554 3 901 2 554 2 723 2 580 3 580 1 580 2 Fig 8 Replacement pa...

Страница 32: ...ling ring up to max 10 bar Profile sealing ring up to max 16 bar O ring max 16 bar 16 10 5 5 5 20 15 10 10 10 25 20 12 12 12 32 25 15 12 12 40 32 20 15 15 50 40 25 15 15 63 50 30 20 20 75 65 35 20 20...

Страница 33: ...70 73 70 73 Tab 14 Maximum sound pressure level sizes SHM50 40S SHM50 40L and SHM65 50 Measuring conditions Distance to the pump 1 m Operation free of cavitation Motor IEC standard motor Tolerance 3...

Страница 34: ...k discharge pressure Operating temperatures Weekly Check motor temperature Undoable screwed connections quarterly Check for correct and tight fitting Impeller Plain bearing Bearing bushes O rings As r...

Страница 35: ...s ET ETL ETLB ETLB S ETLB T ETLB ST to which this declaration relates are in conformity with the following standards Machinery Directive 2006 42 EC EMC Directive 2014 30 EU With regard to electrical h...

Отзывы: