Stübbe Series MDM 902 Скачать руководство пользователя страница 4

General safety instructions

2

General
safety instructions

The manufacturer accepts no liability for damages caused
by disregarding any of the documentation.

2.1

Intended use

The

fi

tting is used for transmitting media pressure to a pressure

gauge.

Use the

fi

tting exclusively transmitting media pressure.

Use the

fi

tting exclusively with a pressure gauge

fi

tted.

Use the

fi

tting exclusively for technically pure media free of

solids (

Resistance list).

Adhere to the operating limits (

Data sheet).

Use the

fi

tting exclusively in the following direction of instal-

lation:

The bottom section mounted on the pressurized pipe

The pressure gauge mounted on the upper part

2.2

General safety instructions

Read and observe the following regulations before carrying
out any work.

2.2.1

Obligations of the operating company

Safety-conscious operation

Only operate the

fi

tting if it is in perfect technical condition

and only use it as intended, staying aware of safety and
risks, and in adherence to the instructions in this manual.

Ensure that the following safety aspects are observed and
monitored:

Intended use

Statutory or other safety and accident-prevention reg-
ulations

Safety regulations governing the handling of haz-
ardous substances

Applicable standards and guidelines in the country
where the pump is operated

Make personal protective equipment available.

Quali

fi

ed personnel

Make sure all personnel tasked with work on the

fi

tting have

read and understood this manual and all other applicable
documents, especially the safety, maintenance and repair
information, before they start any work.

Organize responsibilities, areas of competence and the
supervision of personnel.

The following work should be carried out by specialist tech-
nicians only:

Installation, repair and maintenance work

Work on the electrical system

Make sure that trainee personnel only work on the

fi

tting

under supervision of specialist technicians.

2.2.2

Obligations of personnel

Observe the instructions on the

fi

tting and keep them legi-

ble, e.g. type plate, identi

fi

cation marking for

fl

uid connec-

tions.

Only carry out work on the

fi

tting if the following require-

ments are met:

System is empty

System has been

fl

ushed

System is depressurized

System has cooled down

System is secured against being switched back on
again

Do not make any modi

fi

cations to the device.

2.3

Hazardous media

When handling hazardous media (e.g. hot,

fl

ammable,

explosive, toxic, hazardous to health or the environment),
observe the safety regulations for the handling of haz-
ardous substances.

Use personal protective equipment when carrying out any
work on the

fi

tting.

Collect leaking pumped liquid and residues in a safe man-
ner and dispose of in accordance with environmental reg-
ulations.

4

MDM 902

BA-2017.09.21 EN

301 287

Содержание Series MDM 902

Страница 1: ...N Print No 301 287 TR MA DE Rev001 ASV St bbe GmbH Co KG Hollwieser Stra e 5 32602 Vlotho Germany Phone 49 0 5733 799 0 Fax 49 0 5733 799 5000 E mail contact asv stuebbe de Internet www asv stuebbe co...

Страница 2: ...fitting 7 5 3 1 Fill the fitting 7 5 3 2 Installing and filling the pressure gauge 7 5 4 Installing fitting in pipe 8 5 4 2 Connection with solvent welding butt weld spigot ends 8 5 4 3 Connection wit...

Страница 3: ...other applicable documents especially all safety instructions and warnings 1 2 Other applicable documents To download Resistance lists Resistance of materials used to chemicals www asv stuebbe de pdf_...

Страница 4: ...ere the pump is operated Make personal protective equipment available Qualified personnel Make sure all personnel tasked with work on the fitting have read and understood this manual and all other app...

Страница 5: ...tting is mounted with the bottom section facing the pressurized pipe carrying the medium The pressure gauge is mounted on the upper part The separation diaphragm transmits the media pressure to the pr...

Страница 6: ...erial damage due to inappropriate storage Store the fitting properly 1 Make sure the storage room meets the following condi tions Dry Frost free Vibration free Not in direct sunlight Storage temperatu...

Страница 7: ...fitting Before installation in the pipeline the fitting must be filled and the pressure gauge must be filled and mounted Follow the section drawing for assembly 9 5 Sectional drawing Page 12 Use the...

Страница 8: ...y be performed by technicians who have been specially trained for the pipework in question NOTE Material damage due to contamination of the fitting Make sure no contamination reaches the fitting Flush...

Страница 9: ...e to medium spraying out Use personal protective equipment when carrying out any work on the fitting NOTE Damage to the separation diaphragm due to lack of trans mitter fluid Before commissioning make...

Страница 10: ...nal drawing Page 12 ASV St bbe recommends a contact adhesive such as Pat tex Kraftkleber to bond the bottom section to the upper part 1 Unscrew the pressure gauge 1 anti clockwise from the upper part...

Страница 11: ...dicated causes Error Possible cause Corrective action Incorrect Measurement value Air bubbles in the transmitter fluid Check that the fitting is sufficiently filled with transmitter fluid top it up if...

Страница 12: ...lysantine or Aral Antifreeze Demineralized water Tab 4 Transmitter fluid when used in a potable water area 9 4 Tightening torques Description Torque Pressure gauge hand tight maximal 15 Nm Upper part...