General safety instructions

2

General safety instructions

The manufacturer accepts no liability for damages caused
by disregarding any of the documentation.

2.1

Intended use

Use the

fi

tting exclusively to control pneumatic drives.

Do not use the

fi

tting outdoors.

Use the

fi

tting only for the following media:

Compressed air (oiled or dry)

Nitrogen

Instrument air

2.2

General safety instructions

Read and observe the following regulations before carrying
out any work.

2.2.1

Obligations of the operating company

Safety-conscious working

Only operate the

fi

tting if it is in perfect technical condition

and only use it as intended, remaining aware of safety and
risks, and adhering to the instructions in this manual.

Ensure that the following safety aspects are observed and
monitored:

Intended use

Statutory or other safety and accident-prevention reg-
ulations

Safety regulations governing the handling of haz-
ardous substances

Applicable standards and guidelines in the country
where the pump is operated

Make personal protective equipment available.

Qualified personnel

Ensure all personnel tasked with work on the

fi

tting have

read and understood this manual and all other applicable
documents, especially the safety, maintenance and repair
information, before they start any work.

Organize responsibilities, areas of competence and the
supervision of personnel.

The following work should be carried out by specialist tech-
nicians only:

Installation, repair and maintenance work

Work on the electrical system

Make sure that personnel to be trained only work on the

fi

tting under the supervision of specialist technicians.

2.2.2

Obligations of personnel

Observe the instructions on the

fi

tting and keep them leg-

ible, e.g. name plate and identi

fi

cation marking for

fl

uid

connections.

Only carry out work on the

fi

tting if the following require-

ments are met:

System is empty

System has been

fl

ushed

System is depressurized

System has cooled down

System is secured against being switched back on
again

Do not make any modi

fi

cations to the device.

2.3

Specific hazards

2.3.1

Hazardous media

When handling hazardous media (e.g. hot,

fl

ammable,

explosive, toxic, hazardous to health or the environment),
observe the safety regulations for the handling of haz-
ardous substances.

If the

fi

tting is operated continuously:

Protect the hot surface of the housing from contact with
highly

fl

ammable media.

Avoid skin contact with the hot surface of the housing.

Use personal protective equipment when carrying out any
work on the

fi

tting.

Collect leaking pumped liquid and residues in a safe man-
ner and dispose of in accordance with environmental reg-
ulations.

4

type 6014

BA-2017.10.18 EN

301 302

Содержание 6014 Series

Страница 1: ...N Print No 301 302 TR MA DE Rev001 ASV St bbe GmbH Co KG Hollwieser Stra e 5 32602 Vlotho Germany Phone 49 0 5733 799 0 Fax 49 0 5733 799 5000 E mail contact asv stuebbe de Internet www asv stuebbe co...

Страница 2: ...eumatic valve 7 5 3 Connect fitting to electrical system 7 6 Operation 8 6 1 Commissioning 8 6 2 Manual operation 8 7 Maintenance 8 7 1 Servicing 8 7 2 Maintenance 8 7 2 1 Removing fitting 9 7 3 Repla...

Страница 3: ...w this manual and the other applicable documents especially all safety instructions and warnings 1 2 Other applicable documents To download Type 6014 data sheet Technical data and conditions of operat...

Страница 4: ...pair information before they start any work Organize responsibilities areas of competence and the supervision of personnel The following work should be carried out by specialist tech nicians only Inst...

Страница 5: ...es The fitting consists of a solenoid drive and a housing with a banjo screw The fitting is connected to the control air port of the pneumatic drive The fitting is fitted with manual actuation Mountin...

Страница 6: ...ons Data sheet 4 3 Storage NOTE Material damage due to inappropriate storage Store the fitting properly Make sure the storage room meets the following condi tions Dry Frost free Vibration free Not in...

Страница 7: ...fitting NOTE Material damage from incorrect installation of fitting Use suitable tools Comply with the manufacturer s instructions regarding installation of the pneumatic valve 1 2 3 Fig 4 Installing...

Страница 8: ...arrying out any work on the fitting 7 1 Servicing 1 Visual and function check every three months Normal operating conditions unchanged No leaks No unusual operating noises or vibrations 2 Clean the fi...

Страница 9: ...ng if required Dead space in the fitting may still contain medium 7 3 Replacement parts and return 1 Have the following information ready to hand when order ing spare parts Type plate Fitting type ID...

Страница 10: ...Install fitting in accordance with direction of flow 3 4 Direction of flow Page 5 Valve does not close Plunger disabled Change fitting Connection voltage is cut or insufficient Check supply voltage C...

Страница 11: ...9 mm across flats 5 Tab 4 Tightening torques 9 2 Circuit diagram 2 A 1 P 3 R Fig 6 NC circuit diagram closed when de energized 9 3 Plug assignment DIN EN 175301 803 plug socket The polarity of the con...