Troubleshooting
8
Troubleshooting
WARNING
Risk of injury and poisoning due to hazardous or hot
media.
Use personal protective equipment when carrying out any
work on the
fi
tting.
Safely collect the media and dispose of it in accordance
with environmental regulations.
Consult with the manufacturer regarding faults which are not
identi
fi
ed in the following table, or which cannot be traced to
the indicated causes.
Error
Possible cause
Corrective action
Control connections mixed up
Connect control connections
correctly.
Compressed air connection mixed up at
solenoid pilot valve
Check compressed air connection
and correct if necessary
(
→
supplementary instructions
for drives).
Control function is not right
Electrical connection faulty
Check electric connect and correct
if necessary (
→
supplementary
instructions for limit switch).
Medium escapes between housing and
diaphragm
Housing screws too loose
Tighten housing screws
(
9.2 Tightening torques, Page 13).
Medium escapes at the drive
Diaphragm leaky
7.2.2 Fixing leaks in the port,
Control pressure too low
Check compressed air supply.
Ensure suf
fi
cient air pressure
9.1.2 Control air connections,
Diaphragm leaky
7.2.2 Fixing leaks in the port,
Fitting does not close completely
Drive defective
Replace drive.
Tab. 5
Troubleshooting
12
MV 309
BA-2016.08.04 EN
300 156
Содержание 145039