- 13 -
6 TECHNICAL SPECIFICATION
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.
*Note: Max working pressure is the maximum pressure that can be applied to the pump internal casing under
any installation conditions.
**Note: With footvalve fitted.
Although these pumps are self priming we recommend a footvalve/strainer is used if a suction lift is
required.
6.11
Noise:
The equivalent continuous A-weighted sound pressure level at a
distance of 1 metre from the pump does not exceed 73 dB(A) for Jet 55-45 or
76 dB(A) for Jet 80-45.
Pump Model
Jet 55-45
50 Hz
46587
Jet 80-45
50 Hz
46588
General
Guarantee
1 year
Features
Pump type
Centrifugal
Mechanical seal
EPDM / Carbon / Ceramic
Self priming
ü
ü
Carry handle
ü
ü
Integral on/off switch
ü
ü
Quiet operation
ü
ü
Materials
Pump body
Stainless steel
Impeller
Plastic
Performance
Maximum head (closed valve)
4.5 bar
4.5 bar
Performance @ 10 l/min
3.5 bar
3.8 bar
Performance @ 40 l/min
1.6 bar
2.7 bar
Maximum flow
55 l/min
80 l/min
Manimum static inlet pressure
0.1 bar (1 metre)
Maximum static inlet pressure
0.5 bar (5 metres)
Maximum working pressure*
500 kPa (5 bar)
Maximum ambient air temperature
40
o
C
Min / Max water temperature
Min 4
o
C / Max 35
o
C
Maximum suction lift**
5 metres
Connections
Pump connections
G 1 female (inlet), G 1 female (outlet)
Motor
Type
Induction, auto-reset thermal trip
Duty rating
Continuous (S1)
Electrical
Power supply / phase / frequency
230 V a.c. / 1 / 50 Hz
Current (full load)
2.9 Amps
5.2 Amps
Power consumption
640 Watts
925 Watts
Fuse rating
13 Amps
Power cable (pre-wired)
1.5 metres
Physical
Enclosure protection
IPX4
Length
341 mm
368 mm
Width
217 mm
224 mm
Height (excluding hoses)
238 mm
Weight (including fittings)
6.9 Kg
9.1 Kg