- 12 -
Cont ...
5 MAINTENANCE
5.11
No routine maintenance is required but provision should be made for easy
access to the pump to allow for repairs due to normal wear and tear.
5.12 Disconnect electrical supply before working on pump.
5.13 Turn off water supplies to the pump and release pressure by opening outlets
before attempting maintenance.
5.14. If the installation is fitted with a footvalve and strainer or inline suction strainer,
the strainer must be cleaned as necessary to ensure the pump has unrestricted
flow.
5.15. After maintenance is completed, refer to commissioning section for instructions
on restarting pump.
5.16
Cleaners, Disinfectants and Descalents:
Acid based descalents and aggressive cleaning agents must not
come into contact with the pump. The pump must be removed from
the system prior to the use of these products. The system should be
flushed to remove all chemicals before the pump is re-connected.
If in any doubt as to the suitability of the chemical solutions, please
contact our PumpAssist helpline on +44 (0) 800 31 969 80.