R
Re
ecco
om
mm
me
en
nd
de
ed
d sse
ep
pa
arra
attiio
on
n d
diisstta
an
ncce
ess b
be
ettw
we
ee
en
n p
po
orrtta
ab
blle
e a
an
nd
d m
mo
ob
biille
e R
RF
F cco
om
mm
mu
un
niicca
attiio
on
n e
eq
qu
uiip
pm
me
en
ntt a
an
nd
d tth
he
e 2
28
86
63
3
A
AIIR
R+
+ p
pu
um
mp
p
430-470
GMRS 460;
FRS 460
2.0
0.3
704-787
LTE Band 13, 17
0.2
0.3
800-960
GSM 800/900;
TETRA 800;
iDEN 820;
CDMA 850;
LTE Band 5
2.0
0.3
1,700-1,990
GSM 1800;
CDMA 1900;
GSM 1900;
DECT;
LTE Band 1, 3, 4, 25;
UMTS
2.0
0.3
2,400-2,570
Bluetooth;
WLAN;
802.11 b/g/n;
RFID 2450;
LTE Band 7
2.0
0.3
5,100-5,800
WLAN 802.11 a/n
0.2
0.3
For transmitters rated at a maximum output power not listed above, the recommended separation distance
d
in meters
(m) can be estimated using the equation applicable to the frequency of the transmitter, where
P
is the maximum output
power rating of the transmitter in watts (W) according to the transmitter manufacturer.
N
No
otte
e -- These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects, and people.
G
Gu
uiid
da
an
ncce
e a
an
nd
d m
ma
an
nu
uffa
accttu
urre
err’’ss d
de
ecclla
arra
attiio
on
n -- e
elle
eccttrro
om
ma
ag
gn
ne
ettiicc iim
mm
mu
un
niittyy
The 2863 A
AIIR
R+
+ pump is suitable for use in the electromagnetic environment specified below. The customer or the user of
the 2863 A
AIIR
R+
+ pump should assure that it is used in such an environment.
IIm
mm
mu
un
niittyy tte
esstt
IIE
EC
C 6
60
06
60
01
1 tte
esstt lle
evve
ell
C
Co
om
mp
plliia
an
ncce
e lle
evve
ell
E
Elle
eccttrro
om
ma
ag
gn
ne
ettiicc
e
en
nvviirro
on
nm
me
en
ntt--g
gu
uiid
da
an
ncce
e
Electrostatic Discharge
(ESD)
IEC 61000-4-2
+8 kV contact
+15 kV air
+8 kV contact
+15 kV air
Floors should be wood,
concrete, or ceramic tile. If
floors are covered with
synthetic material, the
relative humidity should be
at least 30%.
Electrostatic fast transient/
burst
IEC 61000-4-4
+2 kV for power supply lines
+1 kV for input/ output lines
+2 kV for power supply lines
+1 kV for input/ output lines
Main power quality should
be that of a typical
commercial or hospital
environment.
Surge
IEC 61000-4-5
±1 kV for input/output lines
±1 kV for input/output lines
Main power quality should
be that of a typical
commercial or hospital
environment.
2863-009-002 Rev AA.1
37