1
32” 4K Surgical Display
240-031-050
Страница 1: ...1 32 4K Surgical Display 240 031 050 ...
Страница 2: ...ect on the power cord Damage to the cable can cause fire or electric shock 6 To avoid electric shock avoid removing the bezel 7 This device should not be used adjacent to or stacked with other devices If adjacent or stacked use is necessary the device should be observed to verify normal operation in the configuration in which it will be used 8 Test this device prior to a surgical procedure This de...
Страница 3: ...1 harmonized national standards or the combination should be evaluated for safety 10 To ensure electromagnetic compatibility refer to the Electromagnetic Compatibility section of this manual The 32 4K Surgical Display 240 031 050 must be installed and operated according to the EMC information provided in this manual 11 Pay close attention to the cleaning instructions in this manual A deviation may...
Страница 4: ...re connected Consult the manufacturer or field service technician for help The warranty is void if any of these warnings or cautions is disregarded This product contains electrical waste or electronic equipment It must not be disposed of as unsorted municipal waste and must be collected separately ...
Страница 5: ...232 port and SDC SIDNE port It also supports USB ports 2 for 5V 1A power supply for accessories and peripherals Intended Use 32 4K Surgical Display is intended for video display during surgical procedures The display is a non sterile reusable device not intended for use in the sterile field The display is intended for use by qualified physicians having complete knowledge of these surgical procedur...
Страница 6: ...al grade AC power cord 0240 031 004 Medical Power Supply Model BPM150S24F11 Bridgepower HDMI Cable Cable Cover Part Number Optional Accessories 0240 030 951 15 ft 5 pin DC extension cable Model 1501047 Bridgepower blank or 001 999 0240 030 952 75 ft 5 pin DC extension cable Model 1501047 Bridgepower blank or 001 999 ...
Страница 7: ...lay ON and OFF 4 Power LED Indicates current status 5 PIP Accesses the Picture in Picture adjustment menu 6 Bright Accesses the Brightness adjustment menu 7 Specialty Accesses the Specialty selection menu 8 Input Access the Input selection menu 9 Rotary control Access the on screen and navigates through its function 10 Logo Light Indicates current status Refer to following Power management menu ...
Страница 8: ...Operation DPMS Standby DPMS suspend DPM Off Horizontal Sync Active Inactive Active Inactive Vertical Sync Active Active Inactive Inactive Video Active Blanked Blanked Blanked Power LED GREEN Green Flashing Green Flashing Green Flashing Logo Light White Breathing Light Breathing Light Breathing Light Power Consumption TBD TBD TBD TBD NOTE This monitor automatically returns to normal operation when ...
Страница 9: ...h hard Powers the input DC power On and OFF 4 Handles Aid in display positioning Caution The handles are not intended to bear the entire weight of the display 5 Cable cover hinges Attach the bottom of the cable cover to the display 6 Velcro straps Straps aid in cable management 7 Cable cover Covers and conceals cables 8 Cable cover clips Attach the top of the cable cover to the display ...
Страница 10: ...es of the cable cover onto the bottom rear of the display 2 Snap on the top section of the cable cover to the aligning clips Removing the Cable Cover 1 Pinch the left and right clips and pull the cable cover towards you 2 Remove the cable cover from the left and right hinges ...
Страница 11: ...ear the full weight of the display Removing the Display Handles 1 Using a 3mm hex key loosen the two M4 x 25mm screws and gently pull the handle away from the display Installing the Display Handles 1 Align the handle with the screw holes on the rear of the display 2 With using a 3mm hex key install the two M4 x 25mm screws to attach the handle ...
Страница 12: ...elp set up your device and instruct you and your staff on its operation and maintenance To schedule an inservice contact your local Stryker Endoscopy representative after your device has arrived Connections 32 4K Surgical Display Connection Ports Video input and output signals are connected to the rear of the display as illustrated below 1 Power Connector 24V 2 DVI 3 HDMI 4 HDMI 4K 5 RS 232 6 SDC ...
Страница 13: ...nect the AC power cord to the power supply 3 Connect the AC power using the supplied hospital grade power cord 4 Optional not shown Connect an extension cord between the power supply and display 5 Install cable cover Power supply information Model Number BPM150S24F11 Manufacturer Bridgepower Corp ...
Страница 14: ...e Mode Picture in Picture Picture by Picture Picture on Picture 2 Bright Activates the Brightness adjustment menu 3 Specialty Activates the Specialty adjustment menu 4 Input Activates the Input selection menu Use the Rotary Control to navigate the on screen menus once they are activated Push Accesses selects on screen display menu Turn Right Left With the on screen display menu activated turning i...
Страница 15: ...ss the Rotary Control to enter the next level OSD 4 Rotate the Rotary Control to increase or decrease the value of the selected parameter or to make a selection on different options 5 To exit the OSD menu screen from the second or third level OSD menu select the Exit option To completely exit the OSD press and hold the Rotary Control If no keys are pressed the OSD will automatically exit after the...
Страница 16: ...16 Troubleshooting Before returning your display for service consult the troubleshooting list below ...
Страница 17: ...Cleaning To clean the display or the power supply 1 If the display cover is in place remove the cover prior to cleaning 2 Apply standard disinfectant or mild detergent to a dry sterile cloth 3 Wipe the display or power supply 4 Take extra care when cleaning the display screen Excess liquid or drips that enter the bottom of the screen or the power supply receptacle may result in product damage Disp...
Страница 18: ...i re and mechanical hazards only in accordance with ANSI AAMI ES60601 1 and CAN CSA C22 2 No 60601 1 IP23 Protection against access to hazardous parts from fingers or similar objects protection from ingress of spraying water less than 60 from vertical Continuous Operation Compliance FCC Regulations FCC Part 15 Class B FCC Identifier QVXAMM320ES ...
Страница 19: ...hich it will be used prior to using it in a surgical procedure Consult the tables below for guidance in placing the display Guidance and Manufacturer s Declaration Electromagnetic Emissions 32 4K Surgical Display is intended for use in the electromagnetic environment specified below The customer or the user of the display should ensure it is used in such an environment Emissions test Compliance El...
Страница 20: ...ip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec Mains power quality should be that of a typical commercial or hospital environment If the user of the transmitter requires continued operation during power mai...
Страница 21: ... radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which 32 4K Surgical Display is used exceeds the applicable RF compliance level above the display and transmitter should be observed to verify no...
Страница 22: ... W according to the transmitter manufacturer Note 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies Note 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Hereby Stryker declares that 32 4K Surgical Display is in compliance with the essential requirements an...
Страница 23: ...23 Symbols and Definitions The following symbols appear on the product its labeling or the product packaging Each symbol carries a special definition as defined below ...