background image

    Transmitter: 
         Receiver:

0240031065
0240031075

         

SYNK® 4K Wireless System

DRAFT

Содержание 0240031065

Страница 1: ...Transmitter Receiver 0240031065 0240031075 SYNK 4K Wireless System D R A F T ...

Страница 2: ...D R A F T ...

Страница 3: ...e AC Adapter 13 Connecting Power to the Receiver from a Display 13 Setting up the SYNK 4K Wireless System 13 Wireless Configuration 16 Operation 17 Pairing the Devices Using a Temporary Token Blue 17 Pairing the Devices Using a Permanent Token Red 17 Removing a Permanent Link 18 Troubleshooting 19 Cleaning 21 Cleaning and Disinfecting the Transmitter Receiver and Tokens 21 Materials and Equipment ...

Страница 4: ...Electromagnetic Compatibility 28 Symbol Definitions 32 D R A F T ...

Страница 5: ...n operating room that complies with all applicable IEC CEC and NEC requirements for safety of electrical devices Any installation or connection with other devices shall be evaluated for electrical safety according to the IEC 60601 1 6 This product is non sterile and therefore should not be placed in the sterile field 7 Although the device was fully tested at the factory before shipment the user sh...

Страница 6: ...ipment without authorization of the manufacturer 18 Attempt no internal repairs or adjustments not specifically detailed in this operating manual Refer any adjustments modifications and or repairs to Stryker Endoscopy or its authorized representatives 19 Do not touch the device and a patient simultaneously as there is a risk of electric shock 20 Do not touch the patient with signal input or output...

Страница 7: ...ctions in this manual A deviation may cause damage 13 Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the devices Note This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interferenc...

Страница 8: ...lish a private and secure connection A token is a small memory device that is programmed with frequencies allowed to establish a link The receiver can optionally be mounted to the back of the 32 4K Surgical Display 0240031050 and it comes with the necessary mounting hardware A dedicated power supply is included with the transmitter and the receiver to provide power Alternatively a Y cable is provi...

Страница 9: ... 1 HDMI high speed cable 2M P39077 2 Remote cables 0105206758 1 Power supply P27315 2 Temporary tokens blue 0105208884 SYNK 4K Wireless Receiver Package Contents 1 Receiver 0240031075 1 Hospital grade power cord 0105033001 1 Power supply P27315 2 Shoulder bolts P44094 1 Y cable P43614 1 HDMI high speed cable 2M P39077 D R A F T ...

Страница 10: ...g for normal token Green Ready for pairing or Wireless link is established Amber Warning see Troubleshooting Red Error contact service representative 4 Token Slot Token insertion site used to establish a wireless connection 5 Token Initializes a wireless connection after insertion into the transmitter and receiver Note The transmitter emits a pairing sound when a wireless link is established The t...

Страница 11: ...ly 2 Remote 1 Connects to video source remote output 1 3 Remote 2 Connects to video source remote output 2 4 Micro USB Port Maintenance port Stryker use only 5 HDMI Out Connects to a primary display 6 HDMI In Connects to a digital input source 7 AC Power Inlet Connects to AC power adapter D R A F T ...

Страница 12: ...tor Blinking White Waiting for normal token Blinking Green Attempting to pair Green Wireless link is established Amber Warning see Troubleshooting Red Error contact service representative 4 Token Slot Token insertion site used to establish a wireless connection 5 Token Initializes a wireless connection after insertion into the transmitter and receiver D R A F T ...

Страница 13: ...nce port Stryker use only 2 Remote 1 Connects to Connected OR Hub Remote 1 3 Remote 2 Connects to Connected OR Hub Remote 2 4 Micro USB Port Maintenance port Stryker use only 5 HDMI Out Connects to a primary display 6 AC Power Inlet Connects to AC power adapter D R A F T ...

Страница 14: ...magnetic Compatibility section of this manual Device Compatibility For optimal use the SYNK 4K Wireless System is designed to work with the 1688 Camera Control Unit 1688010000 the Connected OR Hub 0240200100 with software version 1 2 3 or higher and the 32 4K Surgical Display 0240031050 All features and instructions described in this user manual apply to this system unless otherwise noted The foll...

Страница 15: ... a roll stand or cart Power off and unplug the receiver and display from the electrical outlets before mounting 1 Insert the provided shoulder bolts into the back of the display 2 Ensure the shoulder bolts are secured before proceeding 3 Align the key holes on the bottom of the receiver with the shoulder bolts D R A F T ...

Страница 16: ...12 on the display 4 Push the receiver forward then rotate it clockwise until you feel it lock firmly into place D R A F T ...

Страница 17: ...supply for usability Replace the power supply if needed 1 Disconnect the display s power supply from the 24 V input on the display 2 Using the provided Y cable connect the display s power supply to the 24 V input on the display 3 Insert the Y cable outlet plug into the receiver s AC power inlet Setting up the SYNK 4K Wireless System The SYNK 4K Wireless System can be set up in a number of differen...

Страница 18: ...OUT on the transmitter can be connected to the HDMI IN on a secondary display 2 Using the provided HDMI cable connect the HDMI OUT on the receiver to the HDMI IN on the primary display 3 Optional Repeat Step 2 for a second receiver 4 Link the receiver to the transmitter with the token If using a temporary token linking is required each time the receiver or transmitter is powered on 5 Optional Link...

Страница 19: ...onnected to the HDMI IN on a secondary display 2 Using a provided remote cable connect the Remote Out 1 on the camera control unit to the Remote 1 on the transmitter 3 Using a provided remote cable connect the Remote Out 2 on the camera control unit to the Remote 2 on the transmitter 4 Using the provided HDMI cable connect the HDMI OUT on the receiver to the HDMI IN 1 4K on the Connected OR Hub 5 ...

Страница 20: ...l and allocate an additional 40 MHz channel as a backup in case of co channel interference Systems that are separated by a large distance may use the same channel Note The SYNK 4K Wireless System uses a proprietary transmission method which cannot connect to or be accessed by 802 11 devices or 5 8 GHz cordless phones In order to make sure that there are enough free channels for each SYNK 4K Wirele...

Страница 21: ...s off as the devices perform startup functions 2 When the LED pulses white insert the temporary token into the token slot on the transmitter 3 When the token LED is green remove the token from the transmitter 4 Within 2 minutes and 30 seconds insert the token into the token slot on the receiver 5 Remove the token from the token slot on the receiver when the token LED flashes green An audible tone ...

Страница 22: ...ps 4 and 5 for a second receiver 7 The system is ready to be linked as described in the temporary linking mode procedure Breaking an Active Link To break a link between a receiver and transmitter either power off the devices or disconnect the HDMI cable from the display for more than 5 minutes An active link cannot be broken by inserting a token into either device Powering off the Devices Unplug t...

Страница 23: ...mance Re orient or relocate the unit Increase separation distance between units Increase separation between other SYNK 4K units Connected OR Hub and other wireless capable devices in the room and adjacent rooms Cycle the power switch on the device and re link If none of these remedies resolve the problem switch to a wired video input on the display and contact your Stryker representative Token LED...

Страница 24: ...20 Wireless link established with some but not all Receivers Cycle the power switch on the device Ensure that the Receiver is within 10 meters of the Transmitter Re insert token into Receiver D R A F T ...

Страница 25: ...o not wipe the rear and bottom of the transmitter or receiver Do not wipe the connecting end of the tokens Do not spray cleaning liquid directly onto the devices Spray cleaning liquid onto a cloth before wiping the devices Do not saturate the cloth Do not allow liquid to collect on the devices Do not immerse the devices in any liquid Do not clean the devices with abrasive products or corrosive cle...

Страница 26: ...nd disinfect the SYNK 4K Transmitter SYNK 4K Receiver and tokens Item Description Cleaning and Disinfection Gloves eye protection etc Wear protective equipment as required by the medical facility Germicidal disposal wipes or germicidal spray and sterile cloth To clean exterior of devices D R A F T ...

Страница 27: ...ker representative or return the device to Stryker for service Device does not power on Visible cuts or breaks in any cables Unacceptable deterioration such as but not limited to corrosion discoloration pitting cracked seals or abnormal noises Storage Store the device in a dry clean and dust free environment at room temperatures Periodic Maintenance Schedule To ensure safe operation of the device ...

Страница 28: ...roperly function or appears to be damaged return it to Stryker for evaluation and or repair Repair through Stryker the equipment manufacturer brings the device back to manufacturer specifications Clean all potentially contaminated devices before returning them to Stryker Disposal This product contains electrical waste or electronic equipment It must not be disposed of as unsorted municipal waste a...

Страница 29: ...mensions 7 7 W x 7 2 D x 1 8 H 19 6 cm W x 18 3 cm D x 4 5 cm H SYNK 4K Receiver Video Digital Input Outputs Output One High Definition Multimedia Interface HDMI Connector which type Video Formats 1080p 1920 x 1080 60 fps 4K 3840 x 2160 60 fps Weight 1 4 lbs 0 6 kg Total Shipping Weight 4 5 lbs 2 0 kg Dimensions 7 7 W x 7 2 D x 1 8 H 19 6 cm W x 18 3 cm D x 4 5 cm H Wireless Frequencies of Operati...

Страница 30: ... Ratings Power Supply Input 100 240 V 50 60 Hz 1 1 A AC DC Adapter Manufacturer XP Power Bridge Power Model AFM30US12 BPM150S24F11 12V 2 5A 24V 2 0A Operating Conditions Temperature Range 10 40 C 50 104 F Relative Humidity Range 25 to 75 Atmospheric Pressure 700 to 1060 hPa Transport and Storage Conditions Temperature Range 18 60 C 0 4 140 F Relative Humidity Range 15 to 90 Atmospheric Pressure 50...

Страница 31: ... in accordance with IEC 60601 1 and CAN CSA C22 2 No 60601 1 Continuous Operation IPX0 Compliance FCC Regulations FCC Identifier SYNK 4K Wireless Transmitter SSH SYNK4KTX FCC Identifier SYNK 4K Wireless Receiver SSH SYNK4KRX IC Regulations IC SYNK 4K Wireless Transmitter 4919C SYNK4KTX IC SYNK 4K Wireless Receiver 4919C SYNK4KRX D R A F T ...

Страница 32: ...ed immunity to such emissions If the devices are used adjacent to or stacked with other equipment observe and verify normal operation of the device in the configuration which it will be used prior to a surgical procedure Equipment which employs radio frequency RF communications may affect the normal function of the device Guidance and Manufacturer s Declaration Electromagnetic Emissions The device...

Страница 33: ...hould be that of a typical commercial or hospital environment Surge IEC61000 4 5 1kV differential mode 2kV common mode 1kV differential mode 2kV common mode Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC61000 4 11 0 Ut 0 5 cycle 0 Ut 1 cycle 70 Ut 25 cycles 0 Ut 5 seconds Mai...

Страница 34: ... compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following Radiated RF IEC 61000 4 3 3 V m 80MHz to 2 7 GHz 3 V m Guidance and Manufacturer s Declaration Electromagnetic Immunity The devices are intended for use in the electromagnetic environment specified below The customer or user of the devices should ensure that they are used in su...

Страница 35: ...E Band 5 Pulse modulation 18 Hz 2 0 0 3 28 870 930 1720 1700 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulation 217 Hz 2 0 0 3 28 1845 1970 2450 2400 2570 Bluetooth WLAN 802 11 b g n RFID 2450 LTE Band 7 Pulse modulation 217 Hz 2 0 0 3 28 5240 5100 5800 WLAN 802 11 a n Pulse modulation 217 Hz 0 2 0 3 9 5500 5785 Note Portable RF communications equipment including periphe...

Страница 36: ...e of manufacture Legal manufacturer Product catalog number Product serial number Quantity Made in USA Denotes compliance to CAN CSA C22 2 No 60601 1 and ANSI AAMI 60601 1 Power on off alternates when button is pushed User Manual Caution This product contains electrical waste or electronic equipment It must not be disposed of as unsorted municipal waste and must be collected separately Radiation em...

Страница 37: ...33 D R A F T ...

Страница 38: ...34 D R A F T ...

Страница 39: ...D R A F T ...

Страница 40: ... patents Stryker Corporation or its divisions or other corporate affiliated entities own use or have applied for the following trademarks or service marks CrossFlow Formula and the Stryker logo All other trademarks are trademarks of their respective owners or holders P43596B 2020 07 WCR NONE D R A F T ...

Отзывы: