background image

Streetwize Accessories   

E-mail: [email protected]   www.streetwizeaccessories.com

1. Check manufacturer’s specification on item to be inflated for correct inflation pressure.
2. Remove valve cap cover from valve stem.
3. Insert proper valve stem adapter into stem connector as far as possible and turn the locking thumb lever to down

position.

4. Insert other end of valve stem adapter into inflatable air valve stem as far as practical.
5. Set the compressor on/off switch to “on” position.
6. Monitor pressure on air pressure gauge. When desired pressure is reached, turn off compressor, turn the locking

thumb lever to up position and remove stem connector from valve stem. Also remove valve stem adapter if
applicable. Replace valve cap on valve stem.

STORAGE: 

This unit may be stored in any position. Make sure the clamps are secure inside the booster cable

storage covers. Store at room temperature. If not used for a prolonged period of time, recharge every 2 months in
the winter and every month in the summer.

SPECIFICATIONS

Battery: 

12 volt 8AH sealed lead acid, maintenance free, spill-proof, rechargeable.

Power Supply DC Output: 

12-volts nominal. Up to 10 Amps with auto reset protector

Power Supply Charging Time: 

24 hours with AC charger;
6 hours to recharge with 12-volt DC charger.

Storage Temperature: 

Store in a cool dry area.

The WEEE symbol 

on this product means that this product should be ethically dismantled or recycled to

minimise environmental impact. Please check with your local authority for more information.

IMPORTANT:

ADDITIONAL SAFETY INFORMATION

This Power Station/Emergency Jumpstart is 

NOT

intended for use by persons (including children) with reduced

physical, sensory or mental capabilities, or lack of experience and knowledge, unless they are supervised or
have been given instruction concerning use of the Power Station/Emergency Jumpstart by a person responsible
for their safety.

EC DECLARATION OF CONFORMITY

In accordance with EN ISO 170504:2004 
We; 

The Ace Supply Co Ltd., T/A Streetwize Accessories

Of; 

Unit 9, Warth Rd Ind Estate, Warth Road, Bury,Lancashire BL9 9NB 

And in accordance with the following Directive(s): 

2004/108/EC      

The Electromagnetic Compatibility Directive

2006/42/EC

The Machinery Directive 

hereby declare that:

SWPP4 - Power Station with Air Compressor

is in conformity with the applicable requirements of the following directives:

EN55014-1:2006, EN55014-2:1997+A1:2001, EN55015:2006+A1:2007, EN61541:1995+A1:2000,
EN61000-3-2:2006, EN61000-3-3:2008, EN61558-1:1997+A1:1998+A11:2003, EN61558-2-4:1997,
EN61558-2:17:1997, EN60950-1:2006, EN60335-1:2002+A1:2004+A2:2006+A11:2004+A12:2006
2011/65/EU Verification Testing Of Restriction Of hazardous Substances (ROHS)

Signed by: Name:

Antony Collier - QC Manager 

Signed at Bury on 18/12/12 

12v

Portable Power Station & Emergency

Jumpstarter with Air Compressor

SWPP4

• High Impact Resistant Rubberized Housing

• 300 AMP Jump Start System

• Reverse Polarity Indicator

• 260 PSI Air Compressor with Pressure Reading Gauge

• 12 Volt Power Station

WELCOME: 

This product has been carefully engineered and manufactured to give you dependable operation.

Please read this manual thoroughly before operating your new product as it contains the information you need to
become familiar with its features and obtain the performance that will bring you continued enjoyment for many
years. Please keep this manual on file for future reference.

IMPORTANT: 

PRIOR TO USE, READ AND UNDERSTAND ALL WARNINGS, CAUTIONS AND INSTRUCTIONS INCLUDED

IN THIS INSTRUCTION MANUAL, AND THOSE PUBLISHED BY YOUR VEHICLE BATTERY MANUFACTURER AND
MANUFACTURER OF ANY DEVICE INTENDED TO BE USED WITH THIS UNIT. RETAIN THESE INSTRUCTIONS FOR
FUTURE REFERENCE.

LOCATION OF CONTROLS

1. High Impact Resistant

Rubberized Housing

2. Jump Start System Power Switch

3. Reverse Polarity Indicator

4. Battery Status Check Button

5. Battery Status Indicator

6. Charging Jack

7. 12 Volt Power Outlet

8. 260PSI Pressure Reading Gauge

9. Air Compressor On/Off Switch

10. AC Charger

11. DC Charger

FIRST AID:

Make sure fresh water and soap are available nearby in case battery acid contacts skin, eyes or

clothing. If contact with battery acid occurs, rinse immediately and thoroughly with water. Then wash with soap and
water. Obtain immediate medical attention if redness, irritation or pain is present. For eye contact, flush eyes for at
least 15 minutes and obtain immediate medical attention.

CAUTIONS

• Never work alone with this product. Make sure that someone is available to give assistance if needed.
• Wear complete eye and clothing protection. Do not touch eyes while working near battery.
• Do not attempt to remove or replace the battery used in this device. When the battery has reached the

end of it’s useful lifetime, take the entire unit to a battery recycling facility.

• For proper and safe operation of the 12 Volt DC power accessory outlets, do not place anything into it

except the plug of the accessory to be used.

• Remove metal personal jewelry, such as rings, bracelets, necklaces and watches while working with a

lead-acid battery. It can produce a short-circuit that may cause severe burns.

• Never charge or jump-start a frozen battery.
• Never allow clamps (positive & negative terminals) to touch together or to connect the same piece of

metal to prevent short-circuits and arcing.

• Do not operate this device while wearing vinyl clothing. Static electricity may be generated when vinyl

clothing is rubbed.

• This product is not intended for use in the rain or temperatures above 130˚F.
• Use only the provided chargers, cables and clamps. Unauthorized parts may damage the unit.
• This product is not a toy. Keep out of the reach of children.
• Keep battery terminals clean. Be careful to keep corrosion from coming in contact with eyes.

RoHS

COMPLIANT

Lancashire

BL9 9NB

SWPP4 Manual AW:Layout 1  15/3/15  11:17  Page 1