Страница 1: ... o n me n t a lTe c h n o l o g i e sL L C I S W K S e r i e s H i g h W a l l I n v e r t e r S p l i t U S E R S M A N U A L E N G L I S H R e a d t h i s M a n u a l b e f o r e t h e o p e r a t i o n a n d k e e p i t f o r r e f e r e n c e R e a d a l l s a f e t y p r e c a u t i o n s o n t h e ma n u a l i mp r o p e r u s e c a n c a u s e s e r i o u s i n j u r y ...
Страница 2: ...n 31 Test operation 31 Attachment Configuration of connection pipe 32 Pipe expanding method 33 Content This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your u...
Страница 3: ...pply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Do not wash the air conditioner with water to avoid electric shock Do not spray water on indoor unit It may cause electric shock or malfunction After removing the filter do not touch fins to avoid injury Do not use fire or hair dryer to dry the filter to avoid de...
Страница 4: ... malfunction Do not spill water on the remote controller otherwise the remote controller may be broken When below phenomenon occurs please turn off air conditioner and disconnect power immediately and then contact the dealer or qualified professionals for service Power cord is overheating or damaged There s abnormal sound during operation Circuit break trips off frequently Air conditioner gives of...
Страница 5: ...If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper tube The appliance shall be installed in accordance with national wiring regulations Installation must be performed in accordance with the requ...
Страница 6: ...nt please contact the supplier for a new one Avoid extending the wire by yourself For the air conditioner with plug the plug should be reachable after finishing installation For the air conditioner without plug an circuit break must be installed in the line If you need to relocate the air conditioner to another place only the qualified person can perform the work Otherwise it may cause personal in...
Страница 7: ...R TIMER ON LIGHT ECO QUIET CLOCK I FEEL OFF HEALTH CLEAN TEMP MODE FAN TURBO SLEEP Remote controller Air inlet Handle Air outlet Indoor unit Outdoor unit Actual product may be different from above graphics please refer to actual products NOTE Display Temp indicator Power indicator ...
Страница 8: ...Press FAN button to set your required fan speed auto fan1 fan2 fan3 fan4 fan5 stepless speed 5 Press or button to select fan blowing angle During operation point the remote control signal sender at the receiving window on indoor unit The distance between signal sender and receiving window should be no more than 8m and there should be no obstacles between them Signal may be interfered easily in the...
Страница 9: ...mode Fan mode Heat mode Clock display Fan button button Left right swing button Light button Timer off button Timer on button Health button Clean button Temp button I feel Left right swing Up down swing button Turbo button Sleep button Clock button ECO button I feel button Quiet button button ON OFF button Mode button Quiet mode Clean mode ECO mode Temp display type Outdoor ambient temp Indoor amb...
Страница 10: ...utton can adjust fan speed Press or button can adjust fan blowing angle After selecting cool mode air conditioner will operate under cool mode Press or button to adjust set temperature Press FAN button to adjust fan speed Press or button to adjust fan blowing angle When selecting dry mode the air conditioner operates at fan1 fan speed can t be adjusted Press or button to adjust fan blowing angle W...
Страница 11: ...tepless speed mode users can adjust the fan speed according to the button or button button Press this button the up down swing function can be started and canceled The remote controller defaults to static swing condition Press MODE button and button at the same time when remote controller OFF to switch between simple swing and static swing In static swing condition pressing this button the swing a...
Страница 12: ...eft right swing louver of air conditioner will swing left right automatically at the maximum angle When selecting with remote controller it s the fixed position swing Left right swing louver of air conditioner will stop at that position as shown by the icon to swing When selecting it s the circulating swing Left right swing louver of air conditioner will swing circularly according to the angle as ...
Страница 13: ...rcularly as below When selecting no display on the remote controller the temperature indicator which on the indoor units will display the set temperature When selecting with remote controller temperature indicator on indoor unit displays indoor ambient temperature When selecting with remote controller temperature indicator on indoor unit displays outdoor ambient temperature Note Outdoor temperatur...
Страница 14: ...n ON and icon on remote controller will blink Press or button within 5s to set the time Press this button another time ON and icon on remote controller will blink Press or button within 5s to set the time Hold or button the time will change quickly until reaching your required time Press TIMER ON to confirm it The word ON will stop blinking icon resumes displaying Cancel TIMER ON Under the conditi...
Страница 15: ... the unit will quit this function This function is no use in fan mode or dry mode ECO button In cool mode press ECO button and the unit will operate under ECO mode Note Remote controller displays Air conditioner will operate at auto speed Set temperature can t be adjusted Under cool mode sleep function can not work with ECO mode together at the same time Change mode will exit the ECO mode LIGHT bu...
Страница 16: ...d then turn on air conditioner that will remain the low temperature heating function After powered on the low temperature heating mode was default to off status In the low temperature heating mode SLEEP and Low temperature heating function cannot start at same time When low temperature heating mode has already started meanwhile you press the SLEEP button the air conditioner will exit low temperatu...
Страница 17: ...commended to use a soft dry cloth or wet cloth to wipe it Note Do not remove the panel when cleaning it Clean filter Open panel Clean filter Installation filter Remove filter Pull out the panel to a certain angle as shown in the fig Use dust catcher or water to clean the filter when the filter is very dirty use the water below 45 C to clean it and then put it in a shady and cool place to dry Insta...
Страница 18: ...s and air outlets are blocked 2 Check whether air switch plug and socket are in good condition 3 Check whether filter is clean 4 Check whether drainage pipe is damaged Checking after use season 1 Disconnect power supply 2 Clean filter and indoor unit s panel Notice for recovery 1 Most of packing materials are recyclable materials Please dispose them in appropriate recycling unit 2 If you want to d...
Страница 19: ...No display when operating remote controller Check whether remote controller appears to be damaged If yes replace it Fluorescent lamp in room Take the remote controller close to indoor unit Turn off the fluoresent lamp and then try it again No air emitted from indoor unit Air inlet or air outlet of indoor unit is blocked Eliminate obstacles Under heating mode indoor temperature is reached to set te...
Страница 20: ...perature to proper range Door and window are open Close door and window Odours are emitted Whether there s odour source such as furniture and cigarette etc Clean the filter Eliminate the odour source Air conditioner operates normally suddenly Whether there s interference such as thunder wireless devices etc Disconnect power put back power and then turn on the unit again Outdoor unit has vapor Heat...
Страница 21: ...nit is leaking Do not repair or refit the air conditioner by yourself If the air conditioner operates under abnormal conditions it may cause malfuntion electric shock or fire hazard Contact us Malfunction analysis Error code Troubleshooting Solution CL Filter filth blockage alert Power off clean filter If the filter is not dirtey turn off the air conditioner for 2s then restart the code will be re...
Страница 22: ...to the obstruction At least 30cm At least 15cm At least 15cm Space to the wall Space to the wall Space to the wall At least 30cm Space to the obstruction At least 15cm At least 200cm Space to the obstruction A t l e a s t 3 0 0 c m S p a c e t o t h e o b s t r u c t i o n Space to the floor Installation drawing ...
Страница 23: ...ion water can be dispersed easily and won t affect other people 3 Select a location which is convenient to connect the outdoor unit and near the power socket 4 Select a location which is out of reach for children 5 The location should be ableto withstand the weight of indoor unit and won t increase noise and vibration 6 The appliance must be installed 2 5m above floor 7 Don t install the indoor un...
Страница 24: ...onal wiring regulations 10 Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only Grounding requirement 1 The air conditioner is the first class electric appliance It must be properly grounding with specialized grounding device by a professional Please make sure it is always grounded effectively otherwise it may cause electric shock 2 The yell...
Страница 25: ...he position of piping hole should be a little lower than the wall mounted frame shown as below Left Wall Φ55 Φ70 Right Mark in the middle of it Level meter Rear piping hole Wall Space to the wall above 150mm Space to the wall above 150mm Φ55 Φ70 Rear piping hole Dimension 1081x327x248 Left Wall Φ55 Right Mark in the middle of it Level meter Rear piping hole Wall Space to the wall above 150mm Space...
Страница 26: ...out the pipe from left or right please cut off the corresponding hole on the bottom case Step 5 Connect the pipe of indoor unit 1 Aim the pipe joint at the corresponding bellmouth 2 Pretightening the union nut with hand 3 Adjust the torque force by referring to the following sheet Place the open end wrench on the pipe joint and place the torque wrench on the union nut Tighten the union nut with to...
Страница 27: ...on wire to the wiring terminal according to the color tighten the screw and then fix the power connection wirewith wire clip 4 Put wiring cover back and then tighten the screw 5 Close the panel Note All wires of indoor unit and outdoor unit should be connected by a professional If the length of power connection wire is insufficient please contact the supplier for a new one Avoid extending the wire...
Страница 28: ...m pass through the wall hole 2 Hang the indoor unit on the wall mounting frame 3 Stuff the gap between pipes and wall hole with sealing gum 4 Fix the wall pipe 5 Check if the indoor unit is installed firmly and closed to the wall Do not bend the drain hose too excessively in order to prevent blocking indoor unit gas pipe indoor and outdoor power cord liquid pipe drain hose band drain hose band con...
Страница 29: ...rder to install drainjoint For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 10000W 16000W 10 expansion screws are needed Step 2 Install drain joint Only for cooling and heating unit 1 Connect the outdoor drain joint into the hole on the chassis as sho...
Страница 30: ... 20 Φ 9 52 30 40 Φ 12 45 55 Φ 16 60 65 Φ 19 70 75 Step 5 Connect indoor and outdoor pipe 1 Remove the wire clip connect the power connection wire and signal control wire only for cooling and heating unit to the wiring terminal according to the color fix them with screws 2 Fix the power connection wire and signal control wire with wire clip only for cooling and heating unit Note After tighten the s...
Страница 31: ...o prevent rain from getting into the room Note The through wall height of drain hose shouldn t be higher than the outlet pipe hole of indoor unit The water outlet can t be placed in water in order to drain smoothly Slant the drain hose slightly downwards The drain hose can t be curved raised and fiuctuant etc The drain hose can t raise upwards The water outlet can t be placedin water The drain hos...
Страница 32: ...th leakage detector Check if there is leakage with leakage detector 2 With soap water If leakage detector is not available please use soap water for leakage detection Apply soap water at the suspected position and keep the soap water for more than 3min If there are air bubbles coming out of this position there s a leakage liquid valve gas valve refrigerant charging vent nut of refrigerant charging...
Страница 33: ...ectric leakage Does the power cord follow the specification It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet It may cause in sufficient cooling heating capacity The dust and sundries caused during installation are removed It may cause malfunction or damaging the parts The gas valve and liquid valve of connection pipe are open completely It may cau...
Страница 34: ...ndard length you should add 5ml of refrigerant oil for each additional 5m of connection pipe The calculation method of additional refrigerant charging amount on the basis of liquid pipe Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter Basing on the length of standard pipe add refrigerant according to the requirement as shown in...
Страница 35: ... D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port with expander expander hard mold pipe Note A is different according to the diameter please refer to the sheet below Outer diameter mm A mm Max Min Φ6 6 35 1 4 1 3 0 7 Φ9 52 3 8 1 6 1 0 Φ12 12 7 1 2 1 8 1 0 Φ15 8 16 5 8 2 4 ...
Страница 36: ...I S W K I 3 A I M 1 R 0 6 1 6 ...