STRATUS TA10 Series Industrial Air Conditioners User Manual
2nd edition, Rev. C. 

1 - 8 0 0 - 6 3 3 - 0 4 0 5

6

Unpacking STRATUS 

Air Conditioning Equipment 

Always keep air conditioner unit top up as shown by the 
packaging label and arrows. If the unit is to be transported after 
initial unpacking and inspection, place air conditioner back in 
original packing to prevent damage.
For shipment, repack as received and re-band to the pallet. 
Shipping without being strapped to the pallet may result in 
tipping and damage and voids the warranty.

Air conditioners are not designed to be shipped attached to an 
equipment enclosure. If this is required, the air conditioner must 
have sufficient support to prevent damage due to vibration and 
shock. Air conditioners damaged internally, due to being shipped 
attached to enclosures, are warranty voided.

Inspecting the Equipment

STRATUS air conditioning equipment is designed, 
manufactured and packed to prevent damage from normal 
handling,  shock and vibration during shipment. Please be sure 
to inspect your equipment upon receipt to ensure that there is 
no visual or hidden damage.
Upon receipt of the equipment, ensure that it is always top 
side up as indicated by “THIS SIDE UP” labels; this ensures 
that the compressor oil is not displaced. If the equipment has 
been on its side, it must be put upright for at least 24 hours 
before installing or running to be certain the compressor oil has 
returned to the compressor. All physical damage to packing or 
signs of damage to the equipment must be noted on the freight 
bill of lading. Packages must be opened after receipt to inspect 
for any internal /concealed damage to the equipment and to  
verify proper count and order fulfillment. Shipments delivered 
without the pallet, not top-side up, other freight on top, 
damaged or wet should be refused delivery. Contact the 
shipper immediately upon discovery of shipping damage to 
schedule inspection by the freight company. Keep all packing. 
AutomationDirect cannot take responsibility for customer’s  
failure to file freight damage claims on a timely basis.

1000 - 1500 BTU/Hour Models

• 1 Pre-bagged Hanger Bolt Kit includes  
  (8)  - 10-32 x 1/2 Machine Screws/ Unslotted /Indented Hex Washer Head, Steel/ Zinc
  (8)  - #10 Medium Split Lock Washer, Steel/Zinc
  (8)  - #10 Flat Washer/Machine Screw, Steel/Zinc
• Rubber Seal Gasket X-114HT Pre-Cut, QTY 6.5 feet.  NEMA/UL Type 4 and 4X units have gasket installed
• Instruction / Operation Manual 
• Actual Size Mounting Template

2000 - 4000 BTU/Hour Models

• 1 Pre-bagged Hanger Bolt Kit includes  
  (10)  - 1/4 - 20 x 3/4  Machine Screws/ Unslotted/ Indented Hex Washer Head, Steel/Zinc
  (10)  - 1/4  Medium Split Lock Washers, Steel/Zinc
  (10)  - 1/4 Flat Washer/Machine Screw, Steel/Zinc
• Rubber Seal Gasket X-114HT Pre-Cut, QTY 8.5 feet.  NEMA/UL Type 4 and 4X units have gasket installed
• Instruction / Operation Manual 
• Actual Size Mounting Template

5000 - 8000 BTU/Hour Models

• 1 Pre-bagged Hanger Bolt Kit includes  
  (10)  - 1/4 - 20 x 3/4  Machine Screws/ Unslotted/ Indented Hex Washer Head, Steel/Zinc
  (10)  - 1/4  Medium Split Lock Washers, Steel/Zinc
  (10)  - 1/4 Flat Washer/Machine Screw, Steel/Zinc
• Rubber Seal Gasket X-114HT Pre-Cut, QTY 10.0 feet.  NEMA/UL Type 4 and 4X units have gasket installed
• Instruction / Operation Manual 
• Actual Size Mounting Template

What’s in the box

Upon receipt of the STRATUS Air 
Conditioner, please check for the following:

•  Make sure that the box contains all items 

required for installation of your series.

•  Inspect the unit to ensure it was not 

damaged during shipment.

•  Make sure that the part number 

indicated on the serial number label 

corresponds with the part number of 

your order.

Volts                      Amps 

     Phase 

     Hz 60

Refrigerant                                           Ounces

Design Pressure:

Low Side 

  psi  High Side 

  psi

Motor-Compressor Thermally Protected

UL Type 12, 04, 4X Interface to Electronic Enclosure per UL 50 & 508a

Special Purpose

Air Conditioner

S/N

MODEL No.

BTU

/H

NEMA Type

Automation Direct 

• 

800.633.0405

www.automationdirect.com

UL File # SA33404

Input Specification

Refrigerant Type/Weight

Refrigerant Pressure

Enclosure Rating

A/C Unit Serial Number

A/C Unit Model Number

Nameplate Information

Be sure to record the data from the label onto the back 
of the manual and keep in a safe place for warranty.

WARNING: Before operating the air conditioner, 
inspect all electrical wiring to ensure proper  
installation and wiring to the proper power source.  
The minimum circuit amperage must be 125% of the 
air conditioner label amperage listed for the voltage 
selected. 

Содержание TA10 Series

Страница 1: ...1 w w w a u t o m a t i o n d i r e c t c o m STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C TA10 Series User Manual...

Страница 2: ...2nd Edition Rev A Issue Date 12 16 Publication History Issue Date Description of Changes First Edition 08 02 2010 Original Second Edition 06 05 2014 Rev A 12 12 2016 Unit Specifications Amps and Refri...

Страница 3: ...ioning Equipment 6 What s in the Box 6 Nameplate Information 6 Inspecting the Equipment 6 Basic Operation 7 Features 8 Unit Specifications 8 Preliminary Testing 10 Mounting the Air Conditioner 10 Syst...

Страница 4: ...on fonctionne en toute s curit Toute personne qui installe ou utilise cet quipement doit lire la pr sente publica tion et toutes les autres publications pertinentes avant de l installer ou de l utilis...

Страница 5: ...t 770 844 4200 We are available weekdays from 9 00 a m to 6 00 p m Eastern Time We also encourage you to visit our web site where you can find technical and non technical information about our product...

Страница 6: ...re bagged Hanger Bolt Kit includes 8 10 32 x 1 2 Machine Screws Unslotted Indented Hex Washer Head Steel Zinc 8 10 Medium Split Lock Washer Steel Zinc 8 10 Flat Washer Machine Screw Steel Zinc Rubber...

Страница 7: ...than the factory setpoint of 95 F plus the temperature differential of 5 F As the refrigerant pressure builds to a factory setpoint the condenser fan turns on to force air flow across the coils Refrig...

Страница 8: ...efficiency performance high BTU per KWH for minimal electricity cost Auxillary alarm contacts as a standard NEMA Type 12 Unit Specifications Model BTU H Max Ambient Temperature Standard Max Ambient Te...

Страница 9: ...4 80 98 18 00 TA10 060 46 4X 460 60 1 80 142 18 00 NEMA Type 4 Unit Specifications Model BTU H Max Ambient Temperature Standard Max Ambient Temperature Volts Hertz Running Amps Unit Weight lb Refriger...

Страница 10: ...ital Temperature Controller displays any alarms refer to the Digital Temperature Controller section After completing the above check points the electrical enclosure is ready to be prepared for the ins...

Страница 11: ...off an alarm condition is indicated on the front panel and an alarm contact Form C operates for remote alarming Three main conditions can shut down the AC compressor down The condenser high temperatu...

Страница 12: ...ON Measurement unit F Flashing Programming phase Digital Temperature Controller Overview The microprocessor based digital temperature controller performs the functions of controlling the enclosure te...

Страница 13: ...rrow key Press the SET key to display its value 3 Press the UP or DOWN arrow key to change its value 4 Press SET to store the new value and move to the following parameter To exit Press SET UP arrow k...

Страница 14: ...r 3 minutes after initial 30 min delay Alarm relay operates HA2 Condenser high temperature P2 L 145 F for 3 minutes Alarm relay operates compressor off LA2 Condenser low temperature P2 l 50 F for 3 mi...

Страница 15: ...per commercial coil cleaning compounds and thorough back flush rinsing Refer to directions on the cleaning compounds selected Acid wash is not recommended as it reduces the life of the coil Note Do no...

Страница 16: ...er air flow blocked Installation must meet minimum clearance for condenser air flow Adjacent unit heating air Install baffle deflector or move unit s Perform touch test Compressor hot 190 F Suction ac...

Страница 17: ...e c t c o m STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 17 w w w a u t o m a t i o n d i r e c t c o m Typical Frame Size 1 1000 and 1500 BTU H Units Dimensions All d...

Страница 18: ...4 0 5 18 STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 1 8 0 0 6 3 3 0 4 0 5 18 Cutout for Typical Frame Size 1 1000 and 1500 BTU H Units Dimensions All dimensions inc...

Страница 19: ...t c o m STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 19 w w w a u t o m a t i o n d i r e c t c o m Typical Frame Size 2 2000 and 3000 4000 BTU H Units Dimensions All...

Страница 20: ...RATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 1 8 0 0 6 3 3 0 4 0 5 20 Cutouts for Typical Frame Size 2 2000 and 3000 4000 BTU H Units Dimensions 120 and 240V 480V All di...

Страница 21: ...t c o m STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 21 w w w a u t o m a t i o n d i r e c t c o m Dimensions Typical Frame Size 3 5000 and 6000 8000 BTU H Units All...

Страница 22: ...RATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 1 8 0 0 6 3 3 0 4 0 5 22 Dimensions Cutouts for Typical Frame Size 3 5000 and 6000 8000 BTU H Units All dimensions inches mi...

Страница 23: ...t i o n d i r e c t c o m STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 23 w w w a u t o m a t i o n d i r e c t c o m Schematic 120 Volt Prewired 22 AWG pigtail 7 ft...

Страница 24: ...1 8 0 0 6 3 3 0 4 0 5 24 STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 1 8 0 0 6 3 3 0 4 0 5 24 Schematic 240V Prewired 22 AWG pigtail 7 ft for Remote Alarming...

Страница 25: ...a t i o n d i r e c t c o m STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 25 w w w a u t o m a t i o n d i r e c t c o m Schematic 480V Prewired 22 AWG pigtail 7 ft fo...

Страница 26: ...ight Refrigerant Pressure Notes and Model Information Replacement Parts Wiring Terminal Blocks for Stratus Air Conditioners Manufacturer Manufacturer Part Description 1000 4000 BTU Models Phoenix Cont...

Страница 27: ...27 w w w a u t o m a t i o n d i r e c t c o m STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C P ower 27 w w w a u t o m a t i o n d i r e c t c o m...

Отзывы: