background image

5

w w w . a u t o m a t i o n d i r e c t . c o m

STRATUS TA10 Series Industrial Air Conditioners User Manual
2nd edition, Rev. C.

5

w w w . a u t o m a t i o n d i r e c t . c o m

Overview of this Publication

Thank you for purchasing a STRATUS Air Conditioner. This manual shows you how to install, program and maintain all 
STRATUS Air Conditioners in the series.

Who Should Read This Manual

This manual contains important information for those who will install, maintain, and/or operate any of the STRATUS Air 
Conditioners. It will provide the information you need to keep your system up and running.

Technical Support

 

By Telephone:  770-844-4200

 

(Mon.-Fri., 9:00 a.m.-6:00 p.m. E.T.)

 

On the Web: support.automationdirect.com

We strive to make our manuals the best in the industry. We rely on your feedback to let us know if we are reaching our goal.
Our technical support group is glad to work with you in answering your questions. If you cannot find the solution to your 
particular situation, or, if for any reason you need additional technical assistance, please call technical support at 

770-844-4200

We are available weekdays from 9:00 a.m. to 6:00 p.m. Eastern Time.
We also encourage you to visit our web site where you can find technical and non-technical information about our products 
and our company. Visit us at 

www.automationdirect.com.

Special Symbols

Introduction

STRATUS air conditioning equipment is carefully designed to cool and dehumidify the air in electronic component  
enclosures. Use this guide as general instructions to properly install and operate the STRATUS air conditioning equipment. 
Read this guide completely before running or installing your STRATUS air conditioning equipment.
Prepare the enclosure that is to be cooled for mounting in accordance with this guide and the template supplied.
Preliminary tests must be performed before mounting or installing the air conditioner.
STRATUS air conditioning equipment must be mounted vertically with a minimum of 5” air space for condenser air return 
and supply. 

When you see the “exclamation mark” icon in the left-hand margin, the paragraph to 
its immediate right will be a warning. This information could prevent injury, loss of 
property, or even death (in extreme cases).

When you see the “notepad” icon in the left-hand margin, the paragraph 
to its immediate right will be a special note.

Содержание TA10 Series

Страница 1: ...1 w w w a u t o m a t i o n d i r e c t c o m STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C TA10 Series User Manual...

Страница 2: ...2nd Edition Rev A Issue Date 12 16 Publication History Issue Date Description of Changes First Edition 08 02 2010 Original Second Edition 06 05 2014 Rev A 12 12 2016 Unit Specifications Amps and Refri...

Страница 3: ...ioning Equipment 6 What s in the Box 6 Nameplate Information 6 Inspecting the Equipment 6 Basic Operation 7 Features 8 Unit Specifications 8 Preliminary Testing 10 Mounting the Air Conditioner 10 Syst...

Страница 4: ...on fonctionne en toute s curit Toute personne qui installe ou utilise cet quipement doit lire la pr sente publica tion et toutes les autres publications pertinentes avant de l installer ou de l utilis...

Страница 5: ...t 770 844 4200 We are available weekdays from 9 00 a m to 6 00 p m Eastern Time We also encourage you to visit our web site where you can find technical and non technical information about our product...

Страница 6: ...re bagged Hanger Bolt Kit includes 8 10 32 x 1 2 Machine Screws Unslotted Indented Hex Washer Head Steel Zinc 8 10 Medium Split Lock Washer Steel Zinc 8 10 Flat Washer Machine Screw Steel Zinc Rubber...

Страница 7: ...than the factory setpoint of 95 F plus the temperature differential of 5 F As the refrigerant pressure builds to a factory setpoint the condenser fan turns on to force air flow across the coils Refrig...

Страница 8: ...efficiency performance high BTU per KWH for minimal electricity cost Auxillary alarm contacts as a standard NEMA Type 12 Unit Specifications Model BTU H Max Ambient Temperature Standard Max Ambient Te...

Страница 9: ...4 80 98 18 00 TA10 060 46 4X 460 60 1 80 142 18 00 NEMA Type 4 Unit Specifications Model BTU H Max Ambient Temperature Standard Max Ambient Temperature Volts Hertz Running Amps Unit Weight lb Refriger...

Страница 10: ...ital Temperature Controller displays any alarms refer to the Digital Temperature Controller section After completing the above check points the electrical enclosure is ready to be prepared for the ins...

Страница 11: ...off an alarm condition is indicated on the front panel and an alarm contact Form C operates for remote alarming Three main conditions can shut down the AC compressor down The condenser high temperatu...

Страница 12: ...ON Measurement unit F Flashing Programming phase Digital Temperature Controller Overview The microprocessor based digital temperature controller performs the functions of controlling the enclosure te...

Страница 13: ...rrow key Press the SET key to display its value 3 Press the UP or DOWN arrow key to change its value 4 Press SET to store the new value and move to the following parameter To exit Press SET UP arrow k...

Страница 14: ...r 3 minutes after initial 30 min delay Alarm relay operates HA2 Condenser high temperature P2 L 145 F for 3 minutes Alarm relay operates compressor off LA2 Condenser low temperature P2 l 50 F for 3 mi...

Страница 15: ...per commercial coil cleaning compounds and thorough back flush rinsing Refer to directions on the cleaning compounds selected Acid wash is not recommended as it reduces the life of the coil Note Do no...

Страница 16: ...er air flow blocked Installation must meet minimum clearance for condenser air flow Adjacent unit heating air Install baffle deflector or move unit s Perform touch test Compressor hot 190 F Suction ac...

Страница 17: ...e c t c o m STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 17 w w w a u t o m a t i o n d i r e c t c o m Typical Frame Size 1 1000 and 1500 BTU H Units Dimensions All d...

Страница 18: ...4 0 5 18 STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 1 8 0 0 6 3 3 0 4 0 5 18 Cutout for Typical Frame Size 1 1000 and 1500 BTU H Units Dimensions All dimensions inc...

Страница 19: ...t c o m STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 19 w w w a u t o m a t i o n d i r e c t c o m Typical Frame Size 2 2000 and 3000 4000 BTU H Units Dimensions All...

Страница 20: ...RATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 1 8 0 0 6 3 3 0 4 0 5 20 Cutouts for Typical Frame Size 2 2000 and 3000 4000 BTU H Units Dimensions 120 and 240V 480V All di...

Страница 21: ...t c o m STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 21 w w w a u t o m a t i o n d i r e c t c o m Dimensions Typical Frame Size 3 5000 and 6000 8000 BTU H Units All...

Страница 22: ...RATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 1 8 0 0 6 3 3 0 4 0 5 22 Dimensions Cutouts for Typical Frame Size 3 5000 and 6000 8000 BTU H Units All dimensions inches mi...

Страница 23: ...t i o n d i r e c t c o m STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 23 w w w a u t o m a t i o n d i r e c t c o m Schematic 120 Volt Prewired 22 AWG pigtail 7 ft...

Страница 24: ...1 8 0 0 6 3 3 0 4 0 5 24 STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 1 8 0 0 6 3 3 0 4 0 5 24 Schematic 240V Prewired 22 AWG pigtail 7 ft for Remote Alarming...

Страница 25: ...a t i o n d i r e c t c o m STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C 25 w w w a u t o m a t i o n d i r e c t c o m Schematic 480V Prewired 22 AWG pigtail 7 ft fo...

Страница 26: ...ight Refrigerant Pressure Notes and Model Information Replacement Parts Wiring Terminal Blocks for Stratus Air Conditioners Manufacturer Manufacturer Part Description 1000 4000 BTU Models Phoenix Cont...

Страница 27: ...27 w w w a u t o m a t i o n d i r e c t c o m STRATUS TA10 Series Industrial Air Conditioners User Manual 2nd edition Rev C P ower 27 w w w a u t o m a t i o n d i r e c t c o m...

Отзывы: