Network Connections
Other Infrastructure Requirements
4-3
ftServer V 2302, V 4304, and V 6308 systems also support separate, class-C Ethernet
subnets for various system components, as describe in
Ethernet Subnet Requirements
ftServer V 2302, V 4304, and V 6308 systems require separate, class-C Ethernet
subnets.
lists the subnet requirements for different system configurations.
Maintenance Network
The CAC or other authorized Stratus service representative uses a maintenance
network for remote service and debugging of components in ftServer V 2302, V 4304,
and V 6308 systems. The maintenance network connects the following components to
two U772 24-Port 10/100 Ethernet Switches:
ftScalable Storage RAID controller modules
RSN console server
UPS units
system PC console
Stratus creates this network when installing the system, and supplies the cables for it
(except for the UPS Ethernet cables which are customer supplied).
Table 4-1. Ethernet Subnet Requirements
System Configuration
Separate Class C Ethernet Subnets
ftServer system
with
an optional network
I/O enclosure
One subnet in the form 10.10.1.
X
to connect the host system to the
maintenance network’s U772 Ethernet switches. See
for more information.
A second subnet in the form 10.20.1.
X
to connect the host system and the
network I/O enclosure.
Additional subnets to connect the host system to site networks
ftServer system
without
an optional
network I/O enclosure
One subnet in the form 10.10.1.
X
to connect the host system to the
maintenance network’s U772 Ethernet switches. See
for more information.
Additional subnets to connect the host system to site networks
Содержание ftServer V 2302
Страница 1: ...Stratus Technologies R624 04 Stratus ftServer V 2302 V 4304 and V 6308 Systems Site Planning Guide ...
Страница 10: ...Preface x Stratus ftServer V 2302 V 4304 and V 6308 Systems Site Planning Guide R624 ...
Страница 47: ...Creating a Floor Plan Space and Component Location Planning 3 11 Figure 3 3 Site Layout Grid 1 square foot ...
Страница 48: ...Creating a Floor Plan 3 12 Stratus ftServer V 2302 V 4304 and V 6308 Systems Site Planning Guide R624 ...
Страница 64: ...AAP87600V PDU Specifications A 8 Stratus ftServer V 2302 V 4304 and V 6308 Systems Site Planning Guide R624 ...