6-14
Major Codes with Minor Codes
41.
42.
Controller Abort Minor Errors (Code: 14, XX)
43.
Note:
Currently minor codes exist for major codes 14, 15 17-20, 22, & 23 only.
Code
Description
Corrective Actions
14,01 Not Used
Not Used
14,02 Report: Attempt to raise mod-
eling base sensor failed
1.
Cycle power
2.
Check to see if the toggle bar is broken.
3.
Check for obstructions preventing X or Y movement
4.
Check the substrate sensor bar is not damaged. If so, replace bar.
5.
Using LED's/test points: Check to see if Z foam box toggles when switch
is activated. If not, check foam sensor and/or Umbilical Cable.
6.
Check for loose pins on J506-2, J506- 7, J301-5, and J301-6. See
Umbilical cable diagram on page
7.
Using LED's/test points: Check to see Z home box toggles when switch
is activated. If not, check Z home switch and/ lower harness J8 pins
14,03 Report: modeling base sensor
up when it should be down.
1.
Cycle power.
2.
Check the substrate sensor assembly for free operation.
3.
Check to see if the sensor arm is broken.
4.
Check connector J506, pins 2 and 7 on the I/O card.
5.
Using LED's/test points: Check to see Z foam box toggles when switch is
activated. If not, check substrate sensor, sensor assembly and/or
lower harness.
14,04 Report: modeling base sensor
down when it should be up.
1.
Push the sensor assembly up if it is down.
2.
Check to see if the tip-wipe brush is set too high.
3.
Run the FZ command using TeraTerm -Verify the sensor is being pushed
all the way up.
4.
Remove, clean and reinstall the substrate sensor assembly.
14,05 Abort : Unexpected contact
with X axis home sensor.
14,06 Abort : Unexpected contact
with X axis EOT sensor.
14,07 Abort : Unexpected contact
with Y axis home sensor.
14,08 Abort : Unexpected contact
with Y axis EOT sensor.
1.
Power cycle the machine.
2.
Check for an obstruction hitting the model.
3.
Check to make sure the homing sensors are clean.
4.
Using LED's/test points: Check if home & limit boxes are checked. If so,
check limit switches and/or Umbilical Cable for X sensors, Y cable for Y
sensors.
5.
Manually move the XY table in X and Y checking for smooth operation.
6.
Check belt tension.
7.
Replace XY table. Failed bearings in the Y drive shaft possible root
cause
14,09 Abort : Unexpected contact
with Z axis home sensor.
14,10 Abort : Unexpected contact
with Z axis EOT sensor.
1.
Check to see if the switch is operating correctly using the LED/test
points on the PDB.
2.
Check to see if there are any obstructions interfering with Z stage
movement.
Содержание uPrint
Страница 1: ...uPrint and uPrint Plus uPrint SE and uPrint SE Plus Service Manual Part No 209010 0001 Rev D...
Страница 11: ...1 2...
Страница 35: ...2 24...
Страница 178: ...uPrint uPrint SE Service Manual 4 131 Figure 4 230 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 179: ...4 132 Figure 4 231 uPrint Plus and uPrint SE Plus measurement points and worksheet BL FL FR BR...
Страница 207: ...4 160 Figure 4 275 uPrint and uPrint SE measurement points and worksheet BL FL FR BR...
Страница 267: ...5 58...
Страница 343: ...6 76...
Страница 359: ...7 16...
Страница 373: ...8 14...