POWER CONSUMPTION

WORKSTATION REQUIREMENTS

For details, see the Insight Workstation Requirements document available from the Stratasys website.

ELECTRICAL REQUIREMENTS 

AC POWER REQUIREMENTS

• 

50/60 Hz

• 

100-240 VAC

• 

15-7A

• 

1200W dedicated circuit

• 

The grounded electrical outlet must connect to either a Euro or a US power cord plug provided 

and must be located within 2 m (80 inches) of the printer.

Operation of the printer outside this range is not recommended; degradation of performance and shortened 
component life expectancy will be experienced. 

LAN REQUIREMENTS

A LAN connection is required for communication and file transfer functions.

The LAN connection is a 100 base T, Ethernet protocol, RJ45 connector. One CAT5, 10/100 base T cable is 
supplied with the printer, located in the Startup Kit.

The printer will function in either DHCP or Static IP configurations.

Power Consumption 
(while building)

~1080W

Caution: 

Do not use an extension cord or power strip; doing so can result in

intermittent power issues. Connect the power cord directly into the receptacle or
UPS.

Note: 

Printers configured with a network option of UPnP=ON will occasionally 

broadcast a unique system identifier across the network for use by the Insight FDM 
Control Center software application.

Refer to Insight’s user information for workstation requirements. 

Содержание Fortus 250mc

Страница 1: ...Part No 400713 0001_REV_A Fortus 250mc SITE PREPARATION GUIDE...

Страница 2: ...th Stratasys per software copyright No part of this document may be photocopied reproduced or translated into another language without the prior written consent of Stratasys Inc All drawings and infor...

Страница 3: ...tion 3 WORKSTATION REQUIREMENTS 3 ELECTRICAL REQUIREMENTS 3 AC Power Requirements 3 LAN REQUIREMENTS 3 UNINTERRUPTIBLE POWER SUPPLY UPS 4 USE AND INSTALLATION 4 GENERAL INFORMATION 4 Parts List Cable...

Страница 4: ...the ground lead Know the location of equipment branch circuit interrupters or circuit breakers and how to turn them on and off in case of emergency Know the location of fire extinguishers and how to...

Страница 5: ...1 model 1 support User Interface with Display Panel and Keypad HOW TO USE THIS GUIDE This guide provides information for selecting an appropriate location for the Fortus 250mc Information of particula...

Страница 6: ...Air quality conditions with excessive solid particulates conductive or non conductive may result in system damage Air quality conditions in which airborne oils are allowed to accumulate on or within...

Страница 7: ...A LAN connection is required for communication and file transfer functions The LAN connection is a 100 base T Ethernet protocol RJ45 connector One CAT5 10 100 base T cable is supplied with the printe...

Страница 8: ...nd I O Module if used Installation and Operation Guides for instructions on installing the I O module if used into the UPS unit as well as for connecting AC power to the UPS and Fortus system While co...

Страница 9: ...sg Plug 9Pos AMP 205204 9 2 2 Pin Male 24 20 AWG AMP 1 66506 0 3 1 Shell Size 1 9 Pin w Grommets AMP 748677 1 4 2 Jackscrew Pair 4 40 Knurled AMP 747784 3 5 XX x Cable 2 Conductor 22 AWG ALPHA 1172C o...

Страница 10: ...6 Figure 2 UPS Cable Diagram...

Страница 11: ...e system should be 2 8 m 104 in high 2 2 m 86 in wide and 1 9 m 76 in deep For detailed unpacking and setup instructions refer to Chapter 3 of the Fortus 250mc User Guide SITE PREPARATION CHECKLIST EL...

Страница 12: ...aterials and applications call 888 480 3548 or visit www stratasys com DOCUMENTATION FEEDBACK Customers resellers and Stratasys employees are encouraged to send comments about our documentation and tr...

Отзывы: