DT3 CleanStation

DOC-01121 Rev. A

3-6

3  Safety Guidelines

The following general guidelines, together with the instructions provided 
throughout this guide, ensure user safety while operating and maintaining the 
DT3 CleanStation. 

If the system is not operated as specified, the user's 

safety might be compromised!

•  Never operate the DT3 CleanStation while the cover is open.
•  The power cable should be connected at an easily accessible electric socket 

near the DT3 CleanStation.

•  Do not move the DT3 CleanStation so that the power cable becomes taut or 

disconnects from the power socket.

•  A VAC ground fault interrupt (RCD) must be used.
•  Only operate the DT3 CleanStation when wearing neoprene gloves, safety 

goggles and a protective mask.

•  Make sure that the room is properly ventilated. The ventilation system should 

change the air at least four times every hour.

•  Remove parts with the supplied basket or with steel or plastic tongs. Do not 

use aluminum tongs when the cleaning solution is in the DT3 CleanStation.

•  Never move the DT3 CleanStation when there is liquid in the tank.
•  Placing parts in the tank raises the liquid level. Monitor the liquid level of the 

tank to prevent overflowing.

3.1  Alkaline Cleaning Solution Safety Instructions

Wear the following protective clothing when working with the alkaline cleaning 
solution:

•  safety goggles
•  protective mask
•  nitrile gloves
•  boots or closed shoes

Depending on how you plan to handle the alkaline cleaning solution, the 
suggested protective clothing listed above might not be sufficient. Consult 
your company Safety Officer 

before 

handling the solution. 

3.1.1 

Preparing the Alkaline Cleaning Solution

Always add caustic soda to water. Never pour water onto caustic soda. Mixing it 
with water generates heat that could ignite other materials. See DOC-08380, 
"Working with Alkaline Cleaning Solution".

 

3.2  Waste Disposal

Fully cured models present no special safety or health-related issues. However, 
check if local regulations regard cured and partially cured resins as hazardous 
industrial waste, and comply with all applicable regulations governing their 
disposal.

Dispose of the alkaline cleaning solution according to local regulations.

Содержание CleanStation DT3

Страница 1: ...DOC 01121 Rev A DT3 CLEANSTATION USER GUIDE...

Страница 2: ...The specifications on which this document is based are subject to change without notice No part of this book may be reproduced in any form or by any means nor stored in a database or retrieval system...

Страница 3: ...on 9 5 4 Using the Control Panel 9 5 4 1 Setting the Timer 10 5 4 2 Starting the Cleaning Cycle 10 5 4 3 Stopping the Cleaning Cycle 10 5 5 Removing Printed Models 10 5 6 Draining the Tank 11 5 6 1 Dr...

Страница 4: ...ation The customer is responsible for preparing the site as described in this document If you have any questions about the information in this document contact your Stratasys representative 1 2 For Mo...

Страница 5: ...10 Liquid Capacity Liters Gallons 22 7 6 Weight Kilograms Pounds Empty 28 6 63 Full 45 4 up to 100 including models Operating Temperature Celsius Fahrenheit 4 4 C to 85 C 40 F to 185 F Electrical Spe...

Страница 6: ...DT3 CleanStation Never move the DT3 CleanStation when there is liquid in the tank Placing parts in the tank raises the liquid level Monitor the liquid level of the tank to prevent overflowing 3 1 Alka...

Страница 7: ...comes tight or disconnects from the power socket at least 15 cm 6 inches clearance on each side room temperature between 18 C and 25 C 65 F 77 F Recommendations a non slip floor because water may drip...

Страница 8: ...approximately 23 liters 6 gallons Warning Adding too much water to the tank will cause it to overflow Fill the tank until at least 2 54 cm 1 inch below the top of the tank If you fill the tank more t...

Страница 9: ...Cleaning Cycle on the next page 5 4 Using the Control Panel You use the control panel to operate the DT3 CleanStation Figure 3 Control panel Warning Do not change the factory default settings Doing s...

Страница 10: ...le press the infinity and down buttons 5 4 3 Stopping the Cleaning Cycle The DT3 CleanStation stops automatically when the timer counts down to zero To manually stop the cleaning cycle press the infin...

Страница 11: ...ose and drainage valve 4 When the tank is empty close the drainage valve 5 6 2 Draining Alkaline Cleaning Solution Before handling the alkaline solution read Alkaline Cleaning Solution Safety Instruct...

Страница 12: ...gnificant decrease in water circulation there might be a build up of printing material blocking the pump suction strainer or manifold 6 2 1 Cleaning the Pump Suction Strainer Warning Always wear neopr...

Страница 13: ...ing it 5 Dry the jet plate Figure 5 Cleaning the suction strainer If you find a significant amount of material deposits in the suction strainer it might not be necessary to also clean the manifold If...

Страница 14: ...uts 3 Completely remove the pipe clamps and manifold 4 Remove the material deposits blocking the jets by either pulling it through the holes or by flushing the manifold with water Figure 6 Cleaning th...

Страница 15: ...disconnect the DT3 CleanStation from the wall socket and keep the power cable in view so that it is not accidentally plugged back in To check and replace the fuse 1 Disconnect the unit from the wall...

Страница 16: ...ck that the suction strainer and the manifold jets are clear of material deposits see Maintenance on page 12 7 3 Error Messages on the Control Panel If an error is displayed such as Err4 or Err5 conta...

Страница 17: ...www stratasys com ___ THE 3D PRINTING SOLUTIONS COMPANY...

Отзывы: