Installing and Using the Blood Vessel Cleaning Apparatus Kit (Optional) Inserting the BVCA Cleaning Fixture
Page 31
© Copyright 2019 Stratasys. All rights reserved.
Stratasys Confidential
Inserting the BVCA Cleaning Fixture
After installing the BVCA jet plate, you can insert the BVCA cleaning fixture, or the standard
basket for cleaning regular parts.
You should calibrate the pressure approximately every 3 months, or whenever you notice a
higher pressure on the gauge.
1. Place the filter basket from the BVCA kit over the drain at the bottom of the cleaning tank
with the lever up, while pressing down on the lever to secure the filter basket in place.
Figure 26: Filter basket over drain in cleaning tank
2. Place the BVCA cleaning fixture on the front edge of the CSIIP cleaning station with the
manifold on the left.
3. Hold the manifold with your left hand, over the valves, and hold the cross-pieces of the
bottom frame with your right hand.
Caution:
Hold the BVCA cleaning fixture only by the manifold and frame. Do not hold the BVCA
cleaning fixture by the pressure gauge on the manifold, as it may damage the
pressure gauge.
Filter basket
Lever down