System
System Call Forward
Strata CIX Programming Vol.1 12/09
4-21
System
System Call Forward
Program Number(s): 500 and 504
Set up System Call Forward (SCF) parameters using the following programs:
1. In Network eManager, click System > System Call Forward.
2. Enter Program 500 data; enter Program 504 data.
3.
Get
Default
sets all values to factory default.
4. Click
Submit
.
500 / 504 System Call Forward Assignment
Prerequisite Program:
None
This assignment is used to configure up to 32 system call forward patterns. Station DNs are assigned to
these patterns in the station COS assignments.
Note
The Administrator programs the condition of transfer by setting Call Type, Period and Telephone
Status. Destinations 1 and 2 should be programmed after transfer conditions are set.
F
IELD
D
ESCRIPTION
00 System Call
Forward Template
Select the SCF pattern number to configure.
Possible values:0~4 (CIX/CTX100 & CTX28 & CIX40), 0~10 (CIX/CTX670
& CIX200 Basic), 0~32 (CIX/CTX670 Exp), 0~10 (CIX200
Basic HCTU only), 0~48 (CIX1200 Exp. HEXAU or
HEXBU)
(default = no value)
02 Active Telephone
Status
Select the telephone DN status that should cause this SCF pattern to
operate.
Possible values:No Forwarding, Busy, No Answer, Busy No Answer or
DND (default = No Forwarding)
03 Telephone Status
Select the telephone DN status that should cause this SCF pattern to
operate.
Possible values:No Forwarding, Busy, No Answer, Busy No Answer or
DND (default = No Forwarding)
04 Call Type
Select the type of call that should forward in this pattern.
Possible values:CO Loop or Grd, DID, Tie, Ring Transfer and Internal
(default = no value)
05 Period
Select the system time period in which this SCF pattern should operate.
Possible values:Day, Day2 or Night (default = Day)
06 Destination 1
Enter the first destination to which the call should forward.
Possible values:Up to 32 digits (default = no value)
07 Destination 2
Enter an alternate destination to which the call should forward.
Possible values:Up to 32 digits (default = no value)
Содержание CIX 200
Страница 42: ...Network eManager 2 4 Strata CIX Programming Vol 1 12 09 ...
Страница 43: ...Network eManager Strata CIX Programming Vol 1 12 09 2 5 Network eManager ...
Страница 44: ...Network eManager 2 6 Strata CIX Programming Vol 1 12 09 ...
Страница 314: ...This page is intentionally left blank ...
Страница 432: ...This page is intentionally left blank ...
Страница 434: ...This page is intentionally left blank ...
Страница 468: ...This page is intentionally left blank ...
Страница 508: ...THIS IS THE LAST PAGE OF THE DOCUMENT ...