Stoveman Crown20R Скачать руководство пользователя страница 1

 

SAUNA HEATER INSTALLATION AND OPERATING MANUAL

 

Table 1. Heater specifications 
 

1.

 

GENERAL 

Stoveman product range includes various modifications of sauna heaters. You can choose between round and angular shaped 
stoves. The heater may have a door panel made of heat-resistant glass or metal (M). The heater can be heated directly from 
the hot room or have an extended fire chamber (LS) to be heated 
from another room.

  

Declaration of performance for the purchased 
sauna heater type is annexed to the manual. 
 

Choose  the  heater  with  suitable  heating  output  for  your  sauna 
room. Sauna room’s suitable cubage for this heater is given in the 
specifications. 
When  choosing  a  suitable  heater  it  is  important  to  know  that 
uninsulated  wall  and  ceiling  surfaces  (such  as  brick,  glass,  stone 
and concrete surfaces) increase the required output of the heater.  
Our sales assistant or a representative of our factory can assist you 
at  choosing  a  suitable  heater or you  can  use  a  special  application 
for  choosing  the  heater  on  our  website 

www.stoveman.ee

 

http://www.stoveman.ee/kerise-valimine/ 

 

1.1. Heater components 

 (See Fig. 1) 
 

1-

 

Heater stones (not included in the supply) 

2-

 

Steel mesh 

3-

 

Cleaning hatch 

4-

 

Flue gas outlet to be connected with chimney pipe 

5-

 

Heater casing 

6-

 

Fire chamber door 

7-

 

Glass panel door (optional metal door) 

8-

 

Ash drawer 

9-

 

Fire chamber extension for wall penetration (LS models) 

10- Fire grate 

 

 

 

 

 

 

 

 

 

Figure 1. Heater components

 

Type 

Stoveman 20 

Models 

Crown20R;Crown20R-M;Crown20R-LS; 
Crown20R-M-LS 

Heating output in the sauna room 

20 kW 

Sauna room cubage  

12-20 m³ 

Fuel 

Wood logs up to 40 cm in length 

Refuelling loads 

15 kg in three parts 

Minimum required draft  

12 Pa 

Required temperature class of chimney 

T600 

Inner diameter of a chimney pipe to be connected to the 
heater 

115 mm 

Safety distance to combustible materials: 

 sides 

ceiling 

back 
front (from the furnace door) 

 
500 mm 
1200 mm 
500 mm 
1000 mm 

Carbon dioxide emissions at 13% O

2

 content 

0.64% 

Total efficiency  

65% 

Flue gas temperature 

461 °C 

Weight without sauna stones  

97 kg / LS 106 kg     

Weight of sauna stones  

160 kg 

Diameter of sauna stones  

10–15 cm 

Minimum cross-section of ventilation openings 

7850 mm² 

Minimum cross-section of smoke flue 

10200 mm² 

Thickness of furnace walls and ceiling  

5 mm; Heavy-8mm  

Opening of the ash drawer after igniting the stove 

up to 10 mm 

Mass of generated flue gas 

17,2 g/s 

Отзывы: