36
Appendix A - Specifications/Dimensions
StorCase Technology, Inc.
InfoStation User's Guide - Rev. B01
The following InfoStation specifications and dimensions are provided for reference only.
Appendix A - Specifications/Dimensions
Physical
Specifications
Rack Mount
Tower
Height
6.95" (176.5mm)
19.96" (507.0mm)
Width
16.92" (429.8mm)
8.47" (215.1mm)
(1)
Depth
20.57" (522.5mm)
22.96 (583.2mm)
(1)
Includes base
Environmental Specifications
Operating
Storage
Ambient Temperature
0° C to 35° C
-50° C to 75° C
Relative Humidity
(1)
10% to 80%
10% to 90%
Altitude
-1000 to 50,000 ft
-1000 to 50,000 ft
-304m to 15240m
-304m to 15240m
Shock
(2)
10g
60g
(1)
Non-condensing with maximum gradient of 10% per hour
(2)
11 msec pulse width 1/2 sine wave
Weight
60.8 lbs
(2)
71.0 lbs
(2)
(2)
Weight of empty chassis
Total for 4 Blowers 158 CFM
Cooling
Electrical Specifications
(for One Power Supply)
Auto Ranging 400 Watt Power Supply (500W Peak)
AC Input
100 to 120VAC or 200 to 240VAC, 50/60 Hz
DC Output
5V at 21.5 AMPS, 12V at 24.5 AMPS
Chassis Reliability/Maintainability
MTBF
100,000 Hours
MTTR
5 Minutes
Preventive
Maintenance
None