InfoStation User Interface
StorCase Technology, Inc.
InfoStation User's Guide - Rev. B01
The following steps show how to set-up the drive bay SCSI ID via the Display and Control Panel.
NOTE:
Press
CANCEL
at anytime to exit the menu system and return to the Default Display.
The menu system will automatically cancel after 15 seconds of User inactivity.
NOTE:
The drive bay SCSI ID can only be set when the drive bay is inactive (e.g. when
Drive Ready LED is OFF).
1.
Press
ENTER
at the Default Display so that
display =
Status
.
2.
Press
DOWN
until display =
Bay Cfg
.
3.
Press
ENTER
so that display =
SCSI ID
.
4.
Press
ENTER
again until display =
BAY1:0
.
The drive bay can be configured only when the
SCSI ID number is blinking. If the drive bay
contains a drive or is online, SCSI ID will not blink.
5.
Press
ENTER
to change the SCSI ID.
The * next to the ID number indicates current
SCSI ID.
6.
Press
UP
or
DOWN
to change the SCSI ID value.
7.
Press
ENTER
to accept the change.
The ? indicates possible SCSI ID conflict with the
other drive bays in the same enclosure.
8.
Press
UP
or
DOWN
to scroll through each bay
and repeat steps 5-7 to change bay configura-
tion.