background image

 

 

C - ROOF COVER INSTALLATION 

NOTE:

 DO NOT install the cover onto the frame of your building in high wind conditions. A 

slight breeze is the most advantageous for cover installation. To take advantage of the 
breeze, pull the cover up over the arches with the breeze blowing in the cover like a sail 
filled with air. 

1.

 

Insert the 

Lower tensioning tube for roof cover

 (part code 7) into the pockets on 

the end of the 

roof cover

 (part code 8). Then put the 

 32 Plastic plug for base rail 

section 

(part code 12). 

 

Figure 5 

2.

 

Put the 

Roof cover

 (part code 8) EVENLY, CAREFULLY AND SLOWLY atop the frame. 

Adjust the cover so that it is square and evenly centered on the frame. 

 

Figure 6 

3.

 

On the 

Roof cover, c

ut pockets over each ratchet on the base plates, then use the 

Ratchet strap

 (part code 13) to tie down the

 Lower tensioning tubes

Содержание 26x40x10 Container Shelter Single truss

Страница 1: ...1 SHELTER ASSEMBLY MANUAL 26x40x10 Container Shelter Single truss...

Страница 2: ...1 Top bent tube 7 2 Middle bent tube 14 3 Sidewall bent tube 14 4 Connection purlin 30 5 Support tube 12 6 Clip 24 7 Lower tensioning tube for roof cover 2 Groups 8 Roof cover 1 9 Bolt M8x70 88 10 Bol...

Страница 3: ...y to take off snow immediately otherwise it will slide off on its own READ ALL INSTRUCTIONS BEFORE ASSEMBLY 1 Keep the work area clean Accidents are more likely in cluttered areas Do not set up near s...

Страница 4: ...LATION PROCESS A BASE PLATES INSTALLATION Please refer to the Figure 1 to place the base plates Figure 1 1 The measure must be taken from center to center of the base plates Refer to the diagram above...

Страница 5: ...olts M8x70 part code 9 these make one group of arches Please NOTE the direction of the bolt DO NOT install the bolts on the top of the truss where the fabric will rest 2 Insert one end of the assemble...

Страница 6: ...de 10 There are 5 pieces of Connection purlins part code 4 between each arch 4 Install the Support tube part code 5 using the Clip part code 6 Assemble the frame by turns like this Figure 4 5 Then ins...

Страница 7: ...h air 1 Insert the Lower tensioning tube for roof cover part code 7 into the pockets on the end of the roof cover part code 8 Then put the 32 Plastic plug for base rail section part code 12 Figure 5 2...

Страница 8: ...8 Figure 7 4 Weld the Angle seats part code 15 on each container and use the Rope part code 11 to knit the cover on the two external arches Then tie the Rope to the Angle seats Figure 8...

Страница 9: ...hDcssOph2dWa NOTES DO NOT LEAVE THE ROOF COVER UNATTACHED UNDER ANYCIRCUMSTANCES until the final assembly and tightening has been completed The process is quite easy but some tightening adjustments wi...

Отзывы: