![Stoltzen ATHENA 44 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/stoltzen/athena-44/athena-44_user-manual_1381819025.webp)
Stoltzen ATHENA 44 4x4 HDMI 2.0 Matrix
20
Set the parameters (baud rate, data bit, stop bit and parity bit) correctly to ensure
reliable RS232 control.
Baud rate: 9600 Data bit: 8 Stop bit: 1 Parity bit: none
8.2
RS232 Communication Commands
⚫
Case-sensitive.
⚫
“[“, “]” in the commands are for easy recognition only and not necessary in real
operations. Other symbols “#” and “_” are parts of the commands.
⚫
All commands need to be ended with “<CR><LF>”.
8.2.1
System Command
Command
Function
Command Example and
Feedback
#SET_RS232_BAUD [x]
Set the baud rate. [x]=3~7
3 - 9600
4 - 19200
5 - 38400
6 - 57600
7 - 115200
#SET_RS232_BAUD 3
@RS232_BAUD 9600
#SET_POWER [x]
Power on/power off
[x]=0~1
0 - OFF
1 - ON
#SET_POWER 1
@POWER 1
#GET_MATRIX_NAME
Get matrix name.
@Athena 44
#GET_MATRIX_TYPE
Get matrix type.
@4x4 HDMI Matrix
#GET_FIRMWARE_VERSION
Query control’s soft version and
video’s soft version.
@V1.0.2
@CPLD:V1.0.0
#FACTORY_RESET
Reset to factory default setting.
@Factory Default
#GET_SYSINFO
Query all statues and settings.
@GUI Or RS232 Query
Status:
@HDBaseT Matrix
@Athena 44
@V1.0.3
@POWER 1
@HDBT Power ON
…