![Stollmann BlueMod+S/AI Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/stollmann/bluemod-s-ai/bluemod-s-ai_hardware-reference-manual_1381809029.webp)
S/AI
Page 29 of 52
5.6 Power Consumption and Power Down Modes
5.6.1 Terminal I/O Configuration
The following values are typical power consumption values in the different states.
VSUP = 3,0V, T
amb
= 25°C, all GPIOs open, UART inputs at VSUP or GND, SLCK: 32,768 kHz
Condition
Note Slow
clock
SLCK
Current
Consumption
Unit
I
Avg
Advertising Off, UICP not active or serial interface up
internal
ext. sig.
ext. XTAL
tbd.
tbd.
1,1
mA
Advertising Off, UICP active, serial interface down
(1)
internal
ext. sig.
ext. XTAL
tbd.
tbd.
4
µA
Device in reset
(2)
0,625
mA
(1)
IUR-IN# and UART-CTS# signals connected to CMOS high level
(2)
same current consumption w. internal or external slow clock
Table 14: Supply Current Sleep Modes, no Radio Activity