39
B58FC1 0000000094 EN 002
FUNCTIONS
4.6
Anti-lowering guard
⚠
WARNING
Risk of injury and accident due to implement tipping off!
The anti-lowering guard only prevents the front loader from lowering, however, it does not prevent
accidental dumping of the implement. Persons whose presence is required near the load can be injured
by the load falling down.
Do not move the front loader as long as people are standing in the danger zone.
Only start the lifting operation after everybody has left the danger zone.
The anti-lowering guard in compliance with EN 12525/A1 prevents sudden lowering of the front loader.
It is used when working with a raised front loader if the presence of persons is required in the machine's
working area.
The anti-lowering guard is not suitable for use with work cages that are used to transport people.
The operating state of the anti-lowering guard is shown by the lamp on the switch box. If the lamp is on,
the anti-lowering guard is activated. If the lamp is off, the anti-lowering guard is deactivated. In this case,
there may not be any one standing in the working area of the front loader (see
). When
the anti-lowering guard is activated, the
lifting
function is possible and the
lowering
function is locked.
4.7
Additional functions
4.7.1
Additional control circuits
⚠
WARNING
Risk of injury due to unexpected movement of the front loader or implement!
If there is an electrical malfunction, operating elements can be temporarily or permanently out of
function. As a result, it is possible that an unintended function is triggered instead of the selected
implement functions (see
and
). The triggering of unwanted
functions can lead to unexpected movement of the front loader or implement and cause serious injuries.
Before use, check all of the front loader functions without a load.
In case of malfunction, stop working with the front loader immediately and contact the specialist
workshop.
For hydraulic functions of the implement, additional control circuits must be installed. The
corresponding hydraulic couplings are located directly on the valve and are available as plug-in
couplings.