42
Cleaning the Blending Assembly
Suspension Bracket
The Blending Assembly suspension bracket is
installed behind the freezer door. Therefore, it is
only removed to be sanitized when the freezer
barrel is empty. The bracket must be cleaned
and sanitized at least every 30 days, preferably
when the Clean-In-Place procedure is
performed. Follow these instructions to clean
and sanitize the suspension bracket.
NOTE:
YOU CAN USE THIS OPPORTUNITY
TO CLEAN THE FREEZER BARREL AND ITS
PARTS ACCORDING TO MANUFACTURER’S
INSTRUCTIONS.
1. Ensure the freezer barrel is empty. If the
freezer has multiple barrels, ensure all
barrels are empty before proceeding.
2. Remove the door knobs from the freezer
door.
3. Remove the freezer door from the freezer.
4. Remove the suspension bracket from the
freezer door post.
5. Clean the bracket parts using detergent
water and brush if necessary, then rinse
thoroughly with warm water (108°F / 42°C).
6. Submerge the bracket in sanitizer solution
for at least 5 minutes.
7. Remove parts from the sanitizer solution
and place them on a sanitary tray to dry.
8. Install the bracket back onto the freezer
door post.
Содержание Flavor Burst
Страница 2: ......
Страница 9: ...6 PAGE INTENTIONALLY LEFT BLANK...
Страница 11: ...8 General System Overview Figure 1...
Страница 13: ...10 Integrated Cabinet Continued Figure 2...
Страница 17: ...14 Syrup Pump and Related Parts Figure 4...
Страница 19: ...16 Sanitizer Pump and Related Parts Figure 5...
Страница 21: ...18 Electronic Parts and Connections Continued Figure 6...
Страница 23: ...20 Spare Parts Kit Figure 7...
Страница 24: ...21 PAGE INTENTIONALLY LEFT BLANK...
Страница 36: ...33 PAGE INTENTIONALLY LEFT BLANK...
Страница 50: ...47 PAGE INTENTIONALLY LEFT BLANK...
Страница 75: ......
Страница 76: ......