Operation
Steam Tuner Function
The level of hydration of the steam can be set in “Steam” mode using the patented SteamTuner control. The
setting must be made according to the product being cooked and the result you wish to obtain.
The amount of hydration of the steam cannot be adjusted (set to 100%).
Type of cooking
Humidity input
Humidity extraction
Steam
100%
flue vent always
closed
The holding phase is usually the last phase to be set, with the purpose of maintaining the products at or above 65°C (food safe temperature)
without cooking the product.
The holding phase, by default has the humidity set at 20% and the fan speed set at 1.
For effective holding, it is recommended not to adjust the fan speed. When holding roasted products, a humidity setting of 20% - 35% is
recommended, in the case of brazing or stewing, a humidity setting of 90% - 100% is recommended.
To set a holding phase:
A. Select the cooking method “Holding”
B. Set the parameters (temp, time, fan
speed etc.)
C. Load product into the oven, press
“Start” (press “+ NEW PHASE” if
extra phases is required)
Holding Phase
A
B
Friday, 01 April 2020
16:20
O
I
START
Pre-heat
Manual
PHASE 1
120°
85°
C