Page 11
Due to continuous product research and development,
the information contained herein is subject to change without notice.
www.stoddart.com.au
www.stoddart.co.nz
Chloride Test
1. Remove Titrator from bottle and replace bottle cap
immediately
2. Insert lower end of the Titrator into water to be
tested (approx 20mm of water). DO NOT allow
water to touch yellow completion band at top of
Titrator
3. Allow water to completely saturate the wick of
Titrator. Reaction is complete when yellow band
turns dark
4. Note where the white chloride peak falls on the
scale. This represents the unit value
5. Refer to the table to convert the Titrator units into
salt concentration
* Readings greater than 1.4 (32PPM) require a
Reverse Osmosis Unit to be installed
* Readings less than 1.4 (32PPM) require
the Total dissolved solids (TDS) be tested
Total Dissolved Solids (TDS) Test
1. Remove the cover from the TDS meter, turn on by
pressing the On/Off button. The display should read
000
2. Insert lower end of the TDS meter into water to be
tested (approx 20mm of water). DO NOT completely
submerge
3. Wait 5-10 seconds
4. The number displayed on meter is the TDS (Total
Dissolved Solids) of the water expressed in PPM
(parts per million) e.g. TDS = 70PPM
• Contact Stoddart if reading is lower than 20ppm
5. When finished, turn the TDS meter off
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
1
2
3
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
3.8
4.0
4.2
4.4
0.005
0.006
0.007
0.009
0.010
0.011
0.013
0.014
0.016
0.017
0.019
0.021
0.023
0.025
0.027
0.030
32
39
45
53
60
68
77
86
95
106
116
128
140
152
166
180
4.6
4.8
5.0
5.2
5.4
5.6
5.8
0.032
0.035
0.038
0.041
0.044
0.048
0.051
196
212
229
248
267
288
311
6.0
0.055
335
6.2
0.060
361
6.4
0.064
389
6.6
0.069
419
6.8
0.074
452
7.0
0.080
487
7.2
0.087
525
7.4
0.093
567
7.6
0.101
613
Units %NaCI
CI
Units %NaCI
CI
ppm(mg/L)
Limit*
ppm(mg/L)
Installation
IMPORTANT
Selection of the correct water filtration system to suit local wa
-
ter conditions is CRITICAL. Failure to install the correct system
according to the following guidelines will void warranty.
Installation