Stocks AG MM 117A Скачать руководство пользователя страница 1

1 

  
 

 
 

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 

 

Micrometer 

Installation, Calibration and 

Operation 

Software Reference WZ704-000 rev.15 

 

 

 

Electro-Magnetic Compatibility (EMC) 

This product complies with Council Directive 

89/336/EEC when installed and used in accordance 

with the relevant instructions.

 
 
 

Service and Technical Support

 

Stocks Ag Ltd, Cromwell Rd, Wisbech 

CAMBS. PE14 0SD, UK 

Tel: 44 (0) 1945 464909 

Fax: 44 (0) 1945 464985 

www.stocks-ag.co.uk 

 

© Copyright RDS Technology Ltd 2014 

 
 
 
 
 

Document number 

S/DC/500-10-632 : Issue 3 : 14.1.14 

 

\UK632300.DOC 

 
 
 

Содержание MM 117A

Страница 1: ...s with Council Directive 89 336 EEC when installed and used in accordance with the relevant instructions Service and Technical Support Stocks Ag Ltd Cromwell Rd Wisbech CAMBS PE14 0SD UK Tel 44 0 1945...

Страница 2: ...6 Cutout switch 10 3 Normal Operating Mode_________________________ 11 3 1 Operating Summary 11 3 2 Power On Off 12 3 3 Work Status Indicator 12 3 4 Starting and Stopping the Seeder 12 3 5 Pre start f...

Страница 3: ...illing Rate 18 6 3 Drilling Rate Indicator 18 6 4 Changing the Target Rate 19 6 5 Product Calibration 20 6 6 Set Step for Rate Offset 21 7 Hopper level Alarm______________________________ 22 8 Program...

Страница 4: ...the feed motor on and off The feed motor is also switched on and off automatically via the implement mounted cutout finger switch as the implement is raised and lowered Area totals and all calibration...

Страница 5: ...Switch Power supply Junction Box Assy MM119A View on side of J Box Prime button Automatic Cutout Switch TJ252 Radar Sensor TJ237 shown as fitted on Drill but can be fitted on tractor and wired into T...

Страница 6: ...utout Switch Kit supplied with separate PG9 cable Gland 1 TJ235 Head Unit Mounting Kit 1 6m Extension Cable Junction Box Terminator 1 Cable Tie 25 Options MM107A Battery Power Cable fused All Micromet...

Страница 7: ...mum flexibility in positioning the head unit either from the right hand side of the cab from the dashboard or from an overhead position Assemble the two brackets and mounting plate with clamping knobs...

Страница 8: ...oof enclosure Locate it where it is afforded protection from possible water ingress and for neatness e g behind a trim panel or console Figure 3 Head unit connection NOTE The head unit receives its po...

Страница 9: ...the junction box and secure the lead from the sensor at regular intervals using the cable ties provided Connecting a tractor mounted radar sensor Open the Micrometer junction box and remove the sensor...

Страница 10: ...refore recommended that to ensure accurate speed measurement you check the calibration value by performing an Autocal procedure please refer to section 4 4 2 6 Cutout switch The implement mounted cuto...

Страница 11: ...tal 2 2 HOLD continuously for 10 seconds to enter CAL Mode 1 CAL Mode 2 Normal Mode is resumed when the button is released CH Function Units 1 Forward Speed km h 2 Area Total 1 or 2 ha 3 No function 4...

Страница 12: ...s also fitted with a cutout finger switch so that the feed motor starts and stops automatically when the drill is lowered and raised e g on the headlands The pushbutton switch is not effective when th...

Страница 13: ...CONTROL SYSTEM 13 3 6 Cutout Alarm If the forward speed exceeds 2km h with the drill out of work the instrument will alarm by beeping and flashing C out every 5 seconds The alarm will continue until...

Страница 14: ...ncelled temporarily by selecting another channel but will revert to channel 1 and repeat the alarm after 30 seconds until speed is increased NOTE The application rate will not remain proportional belo...

Страница 15: ...he display will show AUtO ready to start the test run fig 7 5 Drive up to the second marker and stop exactly opposite the marker The instrument counts and displays the pulses received from the speed s...

Страница 16: ...zero Press the CAL button to toggle between the two area registers tot 1 and tot 2 The display then shows the area accumulated since that total was last reset 5 2 Zero Area Total 1 Select the total 1...

Страница 17: ...2 then show the programmed implement width fig 12 Default width 4 metres 3 Continue holding the CAL button and PRESS to select the digit decimal point to change 4 HOLD to change the digit or move the...

Страница 18: ...e the drilling rate The rate adjusts by the step programmed in programme mode 3 i e 5 10 15 20 or 25 of the programmed target or base drilling rate 6 3 Drilling Rate Indicator The left indicator is us...

Страница 19: ...the RATE button to increase the target rate or the RATE button to decrease the target rate fig 16 The longer the switch is held the faster the number changes 3 When the desired target rate is displaye...

Страница 20: ...display NOTE If the priming switch is held for long enough to exceed 9999 grams then the instrument will simply show HiGh informing the operator that he must re test to ensure the weight does not exc...

Страница 21: ...or RATE buttons 1 Press and hold the Ha 0 button as you switch the instrument on The instrument is then in programme mode 3 on channel 1 2 Press the Ha 0 button to select channel 3 The display will s...

Страница 22: ...sor is uncovered the instrument defaults to the hopper level channel beeps 5 times and flashes ALAr every 30 seconds The alarm can be cancelled temporarily by selecting another channel but will revert...

Страница 23: ...n while switching instrument on Press and hold RATE button for 10 seconds while switching instrument on Channel selection Press CAL button Press HA 0 button Press RATE button Channel 1 Speed Sensor Fa...

Страница 24: ...n in work the instrument defaults to the rate channel displays StAL and beeps every 30 seconds The metering roll does not turn The metering motor has stalled It is automatically stopped to prevent fur...

Страница 25: ...METER APPLICATOR CONTROL SYSTEM 25 9 Calibration Record Drill Make Model Instrument Serial No Speed Sensor Factor mm pulse Implement Width m Units kg ha Seed Type Application Rate No of rolls Seed Cal...

Страница 26: ...ETER APPLICATOR CONTROL SYSTEM 26 Issue 1 26 2 09 Original Issue derived from UK558 4 DOC Issue 1 1 4 5 09 Amended table in section 8 1 Issue 2 5 8 10 Replaced icons throughout with text Issue 3 14 1...

Отзывы: