background image

 21

20  i-CON Calibration    

(Page 2 of 2)

1. For  an 

Manual  Calibration 

press  and  hold  the  Prime  button  on  the 

junction box, the larger the quantity dispersed the higher the accuracy 
the  final  calibration  factor  will  be,  release  the  prime  button  once       
sufficient product has been dispensed

2. The  estimated  dispensed  weight  (based  on  the  current  calibration     

factor) is displayed

3. Weigh the product dispensed and then enter the measured weight, and press 

4. A new calibration factor is then re-calculated and displayed

5. Your in field min and max speeds will be displayed.  If you find that you cannot achieve your desired field 

speed, then re-configure the feed roll assembly and repeat the calibration procedure (see page 18 for more 
details)

6. Touch           to save the new factor, it is advised to repeat calibration 2 more times to ensure accuracy

GPS Speed                                                                                                                         

The i-CON control system is automatically configured to run with GPS receiver supplied and is a  simple plug 
and play device.   This  system only works outside and if  you are not receiving a  GPS signal an alarm  will    
displayed on the main screen indicating NO GPS. 

Common Calibration Mistakes

 

Ensure you enter the width and required rate correctly – that the decimal point is in the correct position.   
If the rate is 2.5 kg/ha, enter 2.5. (not 25 - which is 25kg/ha)

 

Remember to deduct the weight of the collection bag or bucket – weigh only the contents

 

Ensure you work in grams – not kilograms

 

Ensure you are working in the mode required – either Kilograms per Hectare or Seeds per Square Metre. 
The standard default mode for the i-CON is in Kgs/Ha and you will have to reconfigure the display if you 
want to display Seeds per Square Metre. You do not need to enter or change the TGW if working in Kgs/Ha 
– only if working in Seeds per Square Metre - Refer to the RDS manual, Section 3, page 21, Units and TGW

 

Ensure you check the minimum and maximum speeds displayed, and that they are sensible for your field 
operation. This is the speed range that the i-CON can maintain the required application rate, and depends 
on the width of your machine, the application rate required, and the type and configuration of feed rolls 
fitted

 

Ensure that the speed range will work for you in the field – ensure that your target forward speed will not 
be close to either the minimum or the maximum of the range, and that you have some reserve of speed 
range above and below the in-field forward speed. Ideally your forward speed will be in close to the middle 
of the range

 

If the minimum is too high, for example 4kph then the feed motor will be running too slowly if your for-
ward speed drops towards the minimum as you set in and lift out of work, and this could result in missed 
patches (although the alarm will trigger when either the minimum or maximum speed is reached)

 

If the indicated speed range does not work for your operation, you must change the feed roll configuration 
or the type of feed roll to apply more or less seed, per revolution of the feed mechanism, as required.   
Once completed, recalibrate and note the new speed range.

Ready For Work

    Close the hinged panel and secure with the over centre catches                                                              

Ensure the fan is running – switch junction box fan switch to ON                                                            
Ensure the feed motor is running and agitator motor is switched on if required                                       
Check all outlet pipes are seeding correctly before commencing work 

Содержание FAN JET PRO PLUS i-CON 130

Страница 1: ...Original Instructions Revision 1 August This document must not be copied duplicated or distributed without prior consent All and patent rights apply STOCKS AG LIMITED CROMWELL ROAD WISBECH CAMBRIDGES...

Страница 2: ...12 12 2 OPTIONAL ATV Fitting Kit 12 12 3 OPTIONAL UTV Fitting Kit 12 13 Mounting Plate 13 14 1 i Con Control system 14 14 2 Wiring diagram 14 14 3 Electrical connections 14 15 Machine components 15 16...

Страница 3: ...24m self propelled crop sprayers or tractor with a front linkage Suitable for UTV vehicles and some ATV fitments OPTIONAL fitting kit available see page 10 The operator alone bears the associated ris...

Страница 4: ...ngdom by Statutory Instrument 2008 No 1597 The Supply of Machinery Safety Regulations 2008 as amended The following standards have been applied in the design and construction of this machine BS EN ISO...

Страница 5: ...gdom by Statutory Instrument 2008 No 1597 The Supply of Machinery Safety Regulations 2008 as amended The following standards have been applied in the design and construction of this machine BS EN ISO...

Страница 6: ...aged by normal or excessive wear Warranty expires if damage is caused by external forces operator error modifications Jet washed or if the machine has not been used for its intended use Contact the co...

Страница 7: ...material being applied If unsure contact the material supplier for more information WARNING Always adhere to the warning information as the disc rotates very fast and has sharp edges Granules leave t...

Страница 8: ...tem immediately by pressing and holding down the left hand rubber end cap on the instrument control panel for approx 2 seconds then release to power off 2 Disconnect the power supply by unplugging the...

Страница 9: ...ure the machine is securely mounted 2 Check the power supply and ensure the power cable is connected direct to the vehicle battery 3 Check the feed block assembly s to ensure the feed rollers are clea...

Страница 10: ...Danger due to thrown or flying objects Always maintain a safe distance whilst the machine is in operation WARNING Risk of injury Possible trapping point when tipping hopper WARNING Keep Clear Maintain...

Страница 11: ...ed part number FJ017S 11 3 Storage Disconnect the power supply by unplugging the power cable or removing the fuse in the power cable if storing the ma chine for long periods It is the responsibility o...

Страница 12: ...any rear carriers will not have the load carrying capacity to support the weight of a fully laden Fan Jet mounted on an ATV kit Please check with your ATV supplier as modification may be available The...

Страница 13: ...ential trapping points are noted taking care not to trap hands or fingers The tipping base plate is attached to the chassis by 2 bolts and spacers which act as the pivot and a removable steel pin secu...

Страница 14: ...ery to ensure maximum power Connect the positive wire fused to the positive terminal and negative earth connection to the negative terminal NOTE the disc should rotate in a clockwise direction when vi...

Страница 15: ...will run normally If required the switch can work in the opposite mode by changing the position of the 2 wires inside the switch so that the switch is out of work when the sprung is at rest To change...

Страница 16: ...t your local Stocks dealer for more details Seed Application Rate kg ha or Seeds m2 Forward Speed km hr Minimum Maximum Forward Speed indicator with alarms beyond which the programmed seed rate cannot...

Страница 17: ...isc to reach full speed High application rates Loads the disc more than a lighter rate and can slow it down Incorrect disc angle It must be at least horizontal not angled downwards It is the responsib...

Страница 18: ...products may be toxic If unsure contact your supplier for more 18 2 Feed roller set up The feed rollers are easily changed by removing the feed block as follows NOTE Empty the hopper completely befor...

Страница 19: ...e drive shaft aligns and secure with the supplied screw knobs 4 Secure with the two small blacks PVC knobs supplied 3 Insert the removed feed block into the Calibration Hopper ensure the drive shaft a...

Страница 20: ...ght delivered whilst calibrating If however as a result of the calibration routine you find that you cannot achieve your desired field speed displayed in the top right corner of the screen then re con...

Страница 21: ...n Kgs Ha and you will have to reconfigure the display if you want to display Seeds per Square Metre You do not need to enter or change the TGW if working in Kgs Ha only if working in Seeds per Square...

Страница 22: ...wind disturbance Supplied with a two side arms items 8 9 which enable the deflector kit to be fitted onto the existing Fan Jet chassis or frame The front flap is fully adjustable so that the correct a...

Страница 23: ...23 23 Fan Jet Pro Plus Partsdrawing...

Страница 24: ...1 18 FJ103A 1 Rubber Tensioner 2 Qty x 3 on 130L 19 FJ104A 1 Bobbin 4 Qty x 6 on 130L 20 FJ415D Tipping Pin 1 21 FJ417A Nylon Spacer 2 22 FJ418A Split Ring 1 23 FJ419A 3mm R Pin 1 24 FJ718A Tipping Br...

Страница 25: ...Slot Head CSK Screw 4 Qty x 6 on 130L 76 M5 014 M5 Flat Washer 9 Qty x 11 on 130L 77 M5 017 M5 Nyloc Nut 8 Qty x 10 on 130L 80 M6 007 M6x20 CSK Set Screw 4 81 M6 008 M6x25 Button Head Set Screw 4 82...

Отзывы: