Supported communication objects
11.1.1
ETG.1000.6 EtherCAT specification: 1000 hex – 1FFF hex
The following table includes the supported communication objects for the standardized profile ETG.1000.6 EtherCAT
specification – CANopen over EtherCAT (CoE) Communication Area as well as how the objects are mapped to the
corresponding parameters of STOBER.
Index
Subindex
TxPDO
RxPDO
Name
Comment
1000 hex
0 hex
—
—
Device type
Constant value 20192 hex
Bit 0 – 15: Device profile
number, 192 hex = 402
Bit 16 – 23: Type, 2 Hex = Servo
drive
Bit 24 – 31: Reserved
1001 hex
0 hex
—
—
Error register
1600 hex
1st RxPDO mapping parameter
1600 hex
0 hex
—
✓
Number of mapped
application objects in RxPDO
Constant value of 6
1600 hex
1 hex – 6 hex
—
✓
Application objects
A225[0] - A225[5]
1601 hex
2nd RxPDO mapping
parameter
1601 hex
0 hex
—
✓
Number of mapped
application objects in RxPDO
Constant value of 6
1601 hex
1 hex – 6 hex
—
✓
Application objects
A226[0] - A225[5]
1602 hex
3rd RxPDO mapping parameter
1602 hex
0 hex
—
✓
Number of mapped
application objects in RxPDO
Constant value of 6
1602 hex
1 hex – 6 hex
—
✓
Application objects
A227[0] - A227[5]
1603 hex
4th RxPDO mapping
parameter
1603 hex
0 hex
—
—
Number of mapped
application objects in RxPDO
Constant value of 6
1603 hex
1 hex – 6 hex
—
—
Application objects
A228[0] - A228[5]
1A00 hex
1st TxPDO mapping parameter
1A00 hex
0 hex
—
✓
Number of mapped
application objects in TxPDO
Constant value of 6
1A00 hex
1 hex – 6 hex
—
✓
Application objects
A233[0] - A233[5]
1A01 hex
2nd TxPDO mapping
parameter
1A01 hex
0 hex
—
✓
Number of mapped
application objects in TxPDO
Constant value of 6
1A01 hex
1 hex – 6 hex
—
✓
Application objects
A234[0] - A234[5]
1A02 hex
3rd TxPDO mapping parameter