9.8.5
Position simulation
The parameter indicates which source is used for encoder simulation. The
result of encoder simulation can be observed in
H82
. For the simulated position
to be generated at an interface, the required form of simulation must be set in
the corresponding interface parameters.
The parameter specifies an offset for encoder simulation. This amount is added
to the value from the evaluation of the source parameterized in
H80
. The sum
of the two values used for encoder simulation is displayed in
H82
. 65536 LSBs
correspond to one revolution (see
H82
).
Shows the display generated by the encoder simulation. It is derived from the
selected source position (with the parameterized transmission ratio
H85
and
following) and the offset from
H81
.
65536 LSBs correspond to one simulated revolution.
With 25-bit SSI simulation, bits 27..3 of
H82
therefore correspond to the
position generated via SSI.
With 13-bit SSI simulation, bits 15..3 correspond to the position generated via
SSI.
With incremental encoder simulation the set number of lines per revolution
applies.
Numerator
H85
is divided depending on the selection in
H80
by denominator
H86
,
H87
or
H88
. This makes it possible to calculate mathematically exact gear
ratios as fractions (gear drives, toothed belt drives).
The numerator
H85
is divided by the denominator
H86
. This makes it possible
to calculate mathematically exact gear ratios as fractions (gear drives, toothed
belt drives).
H80
X120-encoder simulation source
version 0
H81
encoder simulation offset
version 0
H85
H81
H86, if H80 = 5:motor encoder
H87, if H80 = 1:G104, 2:virtual master
or 3:master encoder
H88, if H80 = 4:position encoder
H82
2:virtual master
4:Position encoder
5:Motorencoder
6:IGB
1:G104
0:inactive
H80
3:Master encoder
X20 and
BE encoder
H82
encoder simulation raw value
version 0
H85
simulation factor nominator
version 0
H86
simulation factor denominator
version 0
Information
This parameter is only evaluated if the source parameterized in
H80
is set to
5:Motor encoder
.