Local mode
In local mode you can move the drive with setup functions on or in an
emergency mode. If you would like to use local mode, set
A55 key hand
function
=
1:active
on.
You can activate and control local mode with the keys on the drive controller
operator panel.
Detailed information about the drive controller operator panel can be found in
You can activate local mode with the
key and enable the drive in local mode
with the
key. When the drive is enabled in local mode you can move the
drive with the arrow keys. The meaning of the arrow keys in local mode is as
follows:
Please note: If at least one of the
keys is active while local mode is
enabled and you simultaneously press one of the
keys, the movement
will be interrupted. If you release the
keys, the movement will be
continued. If you release the
keys, the drive will stop.
keys
1
I13 tip acceleration
2
I45 tip deceleration
3
I18 tip jerk
When you press the
key, the drive accelerates with ramp
I13 tip
acceleration
and jerk limit
I18 tip jerk
to speed
I12 tip speed
. If you release the
key, the drive will brake with ramp
I45 tip deceleration
until it reaches a
complete stop.
If you press the
key, the drive will accelerate to
I12 tip speed
. The same
applies to acceleration, deceleration and jerk.
If you press the
keys at the same time, the drive brakes to a complete
stop:
Information
Please note:
If the drive is enabled, local mode cannot be activated.
Local mode and the jogging (tipping) function available in the
applications access the same functionality.
The drive can still be moved if an IGB motion bus was projected but
is not active.
Key
Meaning
Move in positive direction at the speed set in
I12
Move in negative direction at the speed set in
I12
Move in positive direction for the distance set in
I14
Move in negative direction for the distance set in
I14