Connection
7
Manual SD6
7.3.7
X5, X6: Motor holding brake
Terminal description X5
Terminal description X6
Information
Note that motor holding brakes from other manufacturers may only
be connected after consultation with STOBER.
Electrical data
Brake
U
1
24–30 V
I
1max
3.0 A
Maximum
switching
frequency
1 Hz
Pin
Designation
Function
5
1BD1
Control brake
6
1BD2
Reference potential
5
6
Pin
Designation
Function
1
Acknowledge-
ment
Acknowledgement input of an optional
switching amplifier for brake diagnostics –
provided the holding brake is connected to
the SD6 indirectly (for example via a coupling
contactor)
2
GND
Reference potential for acknowledgement
+
+ 24 V
Power supply voltage for the brake
Recommended fuse: max. 6 AT
a)
a) Use of a 4 A fuse (slow-blow) is mandatory for a UL-compliant application. The fuse must be
approved according to UL 248.
-
GND
Reference potential for power supply voltage
of the brake
Maximum conductor cross-section
Connection type
Maximum conductor cross-section [mm
2
]
Rigid
2,5
Flexible
2,5
Flexible with cable end,
without plastic sleeve
2,5
Flexible with cable end, with
plastic sleeve
2,5
2 leads with the same cross-
section with double cable end
—
1
_
+
2