![Stober SC6 Series Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/stober/sc6-series/sc6-series_operating-manual_1381241038.webp)
7 | Commissioning
STOBER
38
02/2020 | ID 443025.06
7.3.2
Activating the EtherCAT master
ü
You have already projected all drive controllers of your system using DriveControlSuite and transmitted the project
configuration to the individual drive controllers. The EtherCAT master is connected to the network, all system
components are energized and the infrastructure is ready for operation. You have saved the generated ESI file in the
specified directory.
1.
Start TwinCAT XAE.
ð
The stored ESI file is read in upon program start and the main window of TwinCAT System Manager opens.
Start page
tab is active.
2.
Select
File
>
New
>
Project
.
ð
The
New Project
dialog box opens.
3.
Select
Installed
>
Templates
>
TwinCAT Projects
>
TwinCAT XAE Project (XML format)
.
4.
Name
,
Location
,
Solution name
:
Label the project and enter a save location and an internal project name.
5.
Close the dialog box.
6.
If the runtime package (EtherCAT master) and TwinCAT XAE have been installed on the same PC, they are connected
to each other automatically. Continue to step 12.
7.
If the runtime package (EtherCAT master) and TwinCAT System Manager have been installed on different computers,
you must connect them to each other.
Click on the
<Local>
list field in the TwinCAT XAE toolbar and select
Choose Target System
.
ð
The
Choose Target System
dialog box opens.
8.
Click on
Search (Ethernet)
.
ð
The
Add Route
dialog box opens.
9.
Click on
Broadcast Search
.
ð
All available control systems are listed.
10. Highlight the desired controller, activate the
IP Address
option and confirm with
Add Route
.
ð
The
Logon Information
dialog box opens.
11. Enter the following information for a new device (TwinCAT standard access) and confirm with
OK
:
User name
:
Administrator
Password
:
1
12. Close the dialog box.
13.
Choose Target System
dialog box:
Highlight the previously selected EtherCAT master and confirm with
OK
.
ð
The EtherCAT master is saved as the target system.
14. In order to be able to configure the EtherCAT system online, you must activate Config mode for the TwinCAT XAE
software.
Select the menu
TWINCAT
>
Restart TwinCAT (Config mode)
.
ð
The
Restart TwinCAT System in Config Mode
dialog box opens.
15. Confirm with
OK
.
ð
The EtherCAT master is saved as the target system, TwinCAT XAE is in Config mode.