STOBER
11 | Commissioning
02/2019 | ID 442728.05
165
4.
Velocity
line:
Paste the copied value of the B13 parameter from the clipboard without the unit and
confirm with
ENTER
.
ð
The maximum velocity of the motor has been transferred to the output.
5. Select the
Axis model
wizard >
Limit: Velocity, acceleration, jerk
.
6. I10 Maximal speed:
Limit the maximum velocity of the output taking into account the configured Nominal motor
speed in B13.
7. Determine the limiting values for acceleration and jerk if necessary and enter them into the
associated parameters.
Limiting torque/force (optional)
The specified default values take into account the rated operation together with the overload
reserves.
1. Select the
Axis model
wizard >
Limit: Torque/force
.
2. If the motor force must be limited, adapt the saved values as necessary.
11.3
Testing the project configuration
Before you continue parameterizing your application, we recommend testing your projected axis
model using the jog control panel.
Check your projected axis model as well as your configured electrical and mechanical data for
plausibility by transferring your project configuration to one of your drive controllers for test
purposes and controlling the drive using the jog control panel instead of using a controller.
1. Highlight the relevant drive controller in the project tree and click on the first projected axis
in the project menu >
Wizard
area.
2. Select
Jog control panel
.
3. The predefined test movement variables are standard values. Check them and, if
necessary, change the values such that you can intervene in an emergency before
personal injury or material damage can occur.
Information
Always check the reliability of the standard values before the test start. If they appear too large
or unsuitable compared with the results of the scaling calculator, always replace them with
values that are more suitable for test operation.
Transferring the test configuration
ü
You have verified the predefined test movement variables for plausibility. To be able to
transfer a test configuration to a drive controller, you must connect your PC to the network.
The relevant drive controller is switched on.
1. In the project tree, highlight the module under which you have recorded the drive controller
and click
Connection and assignment
in the project menu.
ð
The
Setting up a connection
window opens.