Connecting wiring
For connecting wiring, observe the terminal specifications in the chapter
.
Cable requirements
Feature
All sizes
Max. cable length
30 m
Tab. 127: Cable length [m]
10.5.15 X103: BE6 – BE9
The binary inputs 6 to 9 are available on terminal X103.
X103 for binary signals
For the evaluation of binary signals at X103, observe the technical data of the drive controller;
see the chapter
.
Terminal
Pin
Designation
Function
5|4|3|2|1
1
BE6
Binary inputs
2
BE7
3
BE8
4
BE9
5
DGND
Reference ground; not bridged with X101, pin
5
Tab. 128: X103 connection description for binary signals
X103 for encoders
If you would like to use X103 as an encoder connection, note the technical data of the evaluable
encoders at X103; see the chapter
.
Information
Note that a master encoder must be connected to axis A or terminal X101.
Single-ended HTL incremental encoders
Terminal
Pin
Designation
Function
5|4|3|2|1
1
BE6
—
2
BE7
N channel
3
BE8
A channel
4
BE9
B channel
5
DGND
Reference ground; not bridged with X101, pin
5
Tab. 129: X103 connection description for single-ended HTL incremental signals, axis B