8
Prozess data transmission PZD
ID 441687.04
WE KEEP THINGS MOVING
Operation manual
30
8.2.1
Example PPO4 with 12-Byte PZD area
Receiving area of th 5th generation of STÖBER inverters
•
Total length: 10 byte
•
Kept in reserve for this example: 2 byte
Sending area of the 5th generation of STÖBER inverters
•
Total length: 10 byte
•
Kept in reserve for this example: 2 byte
When the parameters
A90
/
A94
are set as described here, the data are
automatically mapped by the inverter from and to the parameters.
Parameter
Value
Description
Length [Byte]
A90.0
A180
Device control byte
1
A90.1
I211
Motion control byte
1
A90.2
I210
Control word command posi
2
A90.3
I213
Target position
4
A90.4
I230
Override
2
Parameter
Value
Description
Length [Byte]
A90.0
E200
Device status byte
1
A90.1
I201
Motion status byte
1
A90.2
I200
Status word command posi
2
A90.3
I203
Current position
4
A90.4
E100
Current speed
2