Prozess data transmission PZD
Operation manual
ID 441687.04
WE KEEP THINGS MOVING
29
8
8.2
The mapping
Mapping manages the allocation of incoming data from the bus to the inverter
parameters and vice versa.
The following table describes the parameters required for mapping.
Information
A new mapping does not become active until the following has
taken place:
1. Back up the changed mapping with the
A00
function
Save
values
.
2. Wait until the action is successfully completed.
3. Turn the device off and on again.
The new mapping is now active.
STÖBER Parameter
PNU/
Subindex
Description
A90 PZD Setpoint Mapping Rx
A90.0 1. Mapped Parameter ...
A90.5 6. Mapped Parameter
205A/0
...
205A/5
Up to 6 parameters are selected here to which the received
PZD data are copied with reference values (RV).
A91 PZD Setpoint Mapping 2Rx
A91.0 1. Mapped Parameter ...
A91.5 6. Mapped Parameter
205B/0
...
205B/5
Up to 6 additional parameters can be selected here as
necessary in which the received PZD data are copied.
A93 PZD Setpoint Len
205C / 0
Specifies the total data length in bytes which is to be
accepted by PROFIBUS for the selected setting in
A90
and
A91
. The value corresponds to the sum of the data lengths
of the correctly set parameters which can be mapped on
PZD. If no value or wrong values are entered in
A90
and
A91
, the value 0 appears here (i.e., no data are accepted by
PROFIBUS).
A94 PZD ActValue Mapping Tx
A94.0 1. Mapped Parameter ...
A94.5 6. Mapped Parameter
205E/0
...
205E/5
Up to 6 parameters are selected here which are copied as
actual values (AV) to the PZD data to be sent to the master.
A95 PZD ActValue Mapping 2Tx
A95.0 1. Mapped Parameter ...
A95.5 6. Mapped Parameter
205F/0
...
205F/5
Up to 6 additional parameters can be selected here which
are copied as actual values to the PZD data to be sent to
the master.
A96 PZD ActValue Len
2061/0
Specifies the total data length in bytes which is to be
transferred to PROFIBUS for the selected setting in
A94
and
A95
. The value corresponds to the sum of the data
lengths of the correctly set parameters which can be
mapped on PZD. If no value or wrong values were entered
in
A94
and
A95
, the value 0 appears here (i.e., no data are
accepted by PROFIBUS).