8 | Commissioning
STOBER
56
05/2018 | ID 442461.04
7. Highlight the CiA object for which you would like to extend PDO transmission and confirm
with
OK
.
If the desired CiA object is not included in the directory, enter its index and subindex in the
corresponding fields (if necessary, calculate both indices as described in the chapters
Manufacturer-specific parameters: 2000 hex – 53FF hex and Manufacturer-specific
parameters: A000 hex – D3FF hex).
Also select the data type that matches the data type of the drive controller parameter and
confirm with
OK
.
ð
The selected CiA object or the specified drive controller parameter has been added to
the PDO content of the selected channel.
8. Repeat steps 6 – 7 for all other CiA objects for which you would like to extend PDO
transmission for the selected channel.
9. Switch to the associated DriveControlSuite project and add to the PDO transmission there
in the same way as the additions in AS6 (see Configuring PDO transmission).
ð
The expansion of PDO transmission takes effect the next time the EtherCAT master is
started.