Operating manual

Brakes for Asynchronous Motors / Asynchronous Motors IE2

1

07/2014

WE KEEP THINGS MOVING

ID 442015_en.04

en

This operating instructions is a supplement to the operating 
instructions "System Motors / Asynchronous Motors".
The electromagnetically operated, twin-surface spring 
pressure brake is applied by spring force when not energised 
and is released by an electromagnetic DC coil (Fig. 1, pos. 2) 
or, when stationary, by an optionally installed manual valve 
(Fig 1, pos. 3). The DC coil can be supplied either directly with 
direct current or with an alternating current via a brake 
rectifier (bridge, single-phase or Powerbox, see information 
on the specification plate). When a direct DC supply is 
provided (without a rectifier), a varistor must be installed as 
protection against switching surges.Observe the information 
in the STÖBER catalogue, on the braked motor specification 
plate, in the operating instructions, wiring diagrams and 
safety instructions. 
If in doubt or when documents are lacking, obtain the 
necessary information from the pertaining STÖBER sales 
office or service workshops.

1

Technical data

Technical data for brake see appendix.

1.1 Electrical features Powerbox 

1.2 Current and torque-time diagram in 

dependency on the circuit 
arrangement

It is appropriate to switch on the brakes by the respective 
switch-on time t2 before the motor.

See also Item 3, Electrical connection.

1.3 Formula brake

M

B

 [Nm] - Braking torque

P

20

 [W] - Power input in continuous operation at 20° C

W

NR

 [10

6

·J] - Friction work until next adjustment, 

amplification factor for Powerbox see below! 
(W

NR

=10·W

01

·(L

max

-L

N

))

W

01

 [10

6

·J] - Friction work per 0.1 mm of wear

L

N

 [mm] - Rated air gap

L

max

 [mm] - Maximum air gap

g

min

 [mm] - Min. permissible lining thickness

t

2

 [ms] - Switch-on time (brake release time) up to M = 0 Nm 

t

11 DC

 [ms] - Switch-off time (delay) at S DC

t

11 AC

 [ms] - Switch-off time (delay) at S AC

J

B

 [10

-4

kgm

2

] - Mass moment of inertia

U

DC

 [V

DC

] - Brake voltage

U

AC

 [V] - Brake rectifier voltage

t

2P

 [ms] - Powerbox switch-on time (brake release time) up to 

M = 0 Nm
t

11DCP

 [ms] - (delay) at S DC with Powerbox

t

11ACP

 [ms] - (delay) at S AC with Powerbox

W

NRP

/W

NR

 - Friction work until next adjustment, Powerbox 

(amplification factor)
I

B

 - Brake current

Z

S

 [1/min] - Permitted switching cycles per minute (a 

switching cycle consists of switching on and off once)

2

Installation, adjustment / 
readjustment of the air gap (Fig. 1)

WARNING!

For work on the brake:

X

Secure machine against unintentional movement 
(vertical load, etc.).

The brakes are installed on the drive upon delivery and the 
braking torque and air gap are adjusted to their rated values.

Air gap setting:

Adjust the air gap 

“L”

 to the rated value (L

N

) when the 

maximum air gap (L

max

) is reached due to wear:

- Remove fan guard (1).

Powerbox electrical properties

Powerbox for use 
with

Frame size 63 - 132: Terminal box or 
switch cabinet; 
Size 160 - 225: only in switch cabinet

Input voltage

180 - 300 V

AC

 +/- 0% 

can be used for a wide range
220 - 275 V +/- 5% 50 or 60 Hz

Excitation time

350 ms +/- 10%

Cable length

max. 100 m of brake coil

Current

I

N

 45°C

1,2 A stable; 
2,4 A for 350 ms

Current

I

N

 75°C

0,7 A stable; 
1,4 A for 350 ms

Содержание K38-03

Страница 1: ...20 W Power input in continuous operation at 20 C WNR 106 J Friction work until next adjustment amplification factor for Powerbox see below WNR 10 W01 Lmax LN W01 106 J Friction work per 0 1 mm of wear LN mm Rated air gap Lmax mm Maximum air gap gmin mm Min permissible lining thickness t2 ms Switch on time brake release time up to M 0 Nm t11 DC ms Switch off time delay at S DC t11 AC ms Switch off ...

Страница 2: ... the brake UAC according to specification plate and supply voltage U3AC UAC U3AC x 0 58 Fig 5 UAC U3AC Fig 6 Connection of the brake to motor terminals possible only when the voltages are equal Permissible only for direct starting with supply Connected voltage with Powerbox rectifier 220 277 VAC coil voltage 115 or 127 VDC Observe terminal designations on the component For other designs or other i...

Страница 3: ...pare parts Include the following when ordering replacement parts item no of the part according to the replacement parts lis model designation according to the rating plate serial number according to rating plate You can reach the STÖBER replacement parts service by phone 07231 582 1190 1191 1224 1225 or fax 07231 582 1010 Important notice The replacement parts lists are not assembly instructions T...

Страница 4: ... 8 0 300 110 660 31 9 13 2 L48 20 180L 180M 260 100 612 0 76 5 0 4 1 2 9 6 400 200 1200 80 3 21 2 L48 25 200L 200M 225M 225S 400 110 792 0 88 0 0 5 1 4 12 5 500 270 1620 220 32 0 Typ Mot MB UDC UAC LN Lmax t2P t11DCP t11ACP WNRP ZS WNR Nm V V mm mm ms ms ms 1 min 50 60 Hz K38 03 80K 80L 10 115 220 275 0 2 1 36 1 75 31 26 13 16 78 85 3 9 5 2 40 K38 04 90L 90S 20 115 220 275 0 2 1 6 2 1 50 44 17 21 ...

Отзывы: