Communication requirements
Note the following requirements for the direct connection.
15.4.6.1
Personal firewall
For communication, both DriveControlSuite and the SATMICL communication service must be enabled in the PC's firewall.
Test communication is initiated during the installation of DriveControlSuite that opens a dialog box for enabling
communication in case of an activated firewall. Note that operation on public networks must also be enabled for
communication using mobile network adapters.
The required setup file can be found in the STOBER Download Center at
http://www.stoeber.de/en/download
.
Program/service
Path
DS6A.exe
(DriveControlSuite)
Standard installation:
C:\Program Files (x86)\STOBER\DriveControlSuite\bin
Parallel installation of different versions (version 6.X-X):
C:\Program Files (x86)\STOBER\DriveControlSuite (V 6.X-X)\bin
SATMICLSVC.exe
(SATMICL service)
32-bit Windows 7 or 32-bit Windows 10:
C:\Windows\System32
64-bit Windows 7 or 64-bit Windows 10:
C:\Windows\SysWOW64
Tab. 201: Programs and services
15.4.6.2
Protocols and ports for communication using routers
For communication using routers, the protocols and ports used by DriveControlSuite and the SATMICL communication
service must be enabled in the routers, if applicable.
Protocol
Port
Use
Program/service
UDP/IP
37915
Connection test (inquiry)
SATMICL service
UDP/IP
37916
Node search
SATMICL service
UDP/IP
30001
Primary port for connection
response (response)
SATMICL service
30002 – 39999
Alternative ports for
connection response
(response)
UDP/IP
40000
Primary port for IP address
specification
DriveControlSuite
40001 – 50000
Alternative ports for IP
address specification
TCP/IP
37915
Data transmission
DriveControlSuite
Tab. 202: Protocols and ports for a direct connection